Uniden UBC780XLT manual Feature Highlights

Page 13

Feature Highlights

Trunk Tracking – Follows VHF High Band, UHF, 800MHz trunked public and government service systems just as if conventional two-way communications were used.

Multi-Track– Track more than one trunking system at a time. Scan conventional and trunked systems at the same time.

500 Channels – Program one frequency into each channel. You must have at least one channel programmed to use the Scan mode.

24 Bands, 10 Banks – Includes 24 bands, with Aircraft and 800 MHz.10 banks with 50 channels each are useful for storing similar frequencies to maintain faster scanning cycles or for storing all the frequencies of a trunked system.

25 MHz-1300 MHz – Indicates the range of frequencies that can be searched within the bands of your scanner.

Note: The frequency coverage is not continuous and excludes the 512-806MHz band.

10 Priority Channels – You can assign one priority channel in each bank. Assigning a priority channel allows you to keep track of activity on your most important channel(s) while monitoring other channels for transmissions. You can also assign trunking priority talkgroups.

Preprogrammed Service (SVC) Search – Allows you to toggle through preprogrammed Police, UHF CB, railroad, aircraft, and marine frequencies.

Unique Data Skip – Allows your scanner to skip unwanted data transmissions and reduces birdies.

Memory Backup – If the battery completely discharges or if power is disconnected, the frequencies programmed in your scanner are retained in memory.

Manual Channel Access – Go directly to any channel.

Attenuator – Reduces the signal strength on a per frequency basis.

Turbo Search – Increases the search speed to 300 steps per second. This applies only to transmission bands with 5 kHz steps.

Text Tags – You can customise your scanner by storing text tags (up to 16 characters).

Auto Store – The scanner automatically arranges a memory store for searched frequencies.

CTCSS/DCS – The scanner can receive and search for subaudible tones.

3

Image 13
Contents UBC780XLT Important Notice IntroductionFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Included with Your Scanner Package Connecting an Antenna SetupMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Applying Power Using Standard AC Power Desktop InstallationConnecting an External Speaker Connecting the Clone Cable Connecting an EarphoneConnecting the Tape Recorder Listening SafelyBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System 2SCREEN Mask Menu Description and Numeric Keypad Equivalents0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Storing Frequencies into Channels ProgrammingStoring Text Tags Duplicate Frequency AlertAssigning a Bank Tag to a Bank Assigning a Text Tag to a ChannelProgramming Tips Beep AlertDeleting a Stored Frequency Assigning the beep alert to a channelScanning To directly access a specific channelSetting the Delay Mode RF Attenuation FeatureLockout in Scanning Mode Lockout in Manual ModeChannel Lockout Restoring All Locked-out Channels Restoring a Locked-out ChannelPriority Scan Changing the Priority Channel Searching Setting a Search RangeData Skip Search Hold FeatureFrequency Skip Auto Storing Storing Search FrequenciesSquelch SQ Mode For example, the scanner shows the following displays Additional Menu Options for SearchingService Search Skip Service SearchTrunked Systems Programming Trunking Frequencies Programming and Receiving Trunked SystemsSelecting Trunking System Type Selecting Trunking Programming Menu ModeTrunked Search Receiving Trunked SystemsID Lockout ID Hold and Direct Entry ID Hold ModeRestoring Locked-out IDs Channel Activity IndicatorsTo unlock a single ID, follow these steps To unlock all locked out IDs in a bank at onceProgramming ID Scan Lists Manually Scan ListsTo enter a Type I ID To enter an Edacs ID Program ID Manually with the Menu ModeTo enter a LTR ID ID Scan Mode Programming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Moving between Scan List MemoriesMotorola Type Call Motorola/EDACSMulti-Track Calls in Scan and Manual ModeScan & Search Icons Edacs Tracking Edacs ReceptionAn Edacs Trunked system AFS Partial Entry Feature Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet MapProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Start Remote Mode Remote PC Control ModeRemote Interface To connect Scanner to PCPC Control Parameter Clone ModeChange Transfer Speed To connect the scanner to scannerComplete displays Dimmer Additional FeaturesEnter Lock Key Beep OptionReceiving Mode Selection Reverse ModeFrequency and Channel Tuning with the VFO Control Mute On/OffCare and Maintenance Troubleshooting Page VHF TV SpecificationsGlossary of terms Glossary of TermsPage Appendix Preset Fleet MapsS11 S12 Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts Service Division One Year Limited WarrantyUBZZ01305AZ