Uniden UBC780XLT manual Receiving Trunked Systems, Trunked Search

Page 45

Setting the Squelch

For trunked reception, a good setting for the SQUELCH control is in the centre of the range with the red marker pointing up. See the illustration.

If set too high (CCW) in some cases it could prevent your scanner from locking to the control channel reliably. If set too low (CW) it will slightly delay finding the control channel. The best setting is the same as for conventional reception, and is not critical.

Receiving Trunked Systems

When you have properly programmed all the frequencies for a trunked system, you can receive the system several different ways. You will find that Search, Hold, Lockout, Scan and Manual are all similar to conventional scanning.

TRUNKED SEARCH lets you hear all system talkgroup activity (unit-to-unit I-Calls may be received as well). This is the best way to get started.

ID HOLD works with Search mode to let you quickly freeze reception on an interesting transmission. Or you can manually specify a talkgroup with DIRECT ENTRY ID HOLD.

ID LOCKOUT works with Search to exclude talkgroups that you don't want to hear.

ID SCAN lets you receive only those talkgroups that you store in Scan Lists.

MANUAL lets to selectively listen to a talkgroup in your Scan Lists

When receiving EDACS systems, remember that Uniden's AFS talkgroups give you powerful flexibility. In a few keystrokes, you can specify a single talkgroup, a fleet, or an entire agency in all the above modes. Read the section "EDACS Reception" to understand how this works.

Trunked Search

Once you have programmed all the frequencies for a trunked system, SEARCH will let you immediately start hearing transmissions. It is suggested you try SEARCH mode first.

1.Press SCAN, and select the bank(s) you wish to receive, just as you select banks in conventional scanning.

2.Press TRUNK to enable trunked reception. The radio will seek and acquire the trunked system control channel. The scanner will now be in MONITOR mode. You will hear the control channel and see active talkgroups on the screen. You will not hear the voice transmissions in MONITOR mode.

Hint: MONITOR mode is an excellent way to observe system activity and determine which talkgroups are most active. Locked-out IDs display during MONITOR mode.

3.Press SRCH to begin searching and receiving. You will hear talkgroups and see them on the screen.

Talkgroups display differently in Motorola, EDACS and LTR systems. You should read the appropriate parts of this guide to understand the formats.

35

Image 45
Contents UBC780XLT Important Notice IntroductionFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Included with Your Scanner Package Connecting an Antenna SetupMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Connecting the Clone Cable Connecting an EarphoneConnecting the Tape Recorder Listening SafelySetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System 2SCREEN Mask Menu Description and Numeric Keypad Equivalents0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Storing Frequencies into Channels ProgrammingStoring Text Tags Duplicate Frequency AlertAssigning a Bank Tag to a Bank Assigning a Text Tag to a ChannelProgramming Tips Beep AlertDeleting a Stored Frequency Assigning the beep alert to a channelScanning To directly access a specific channelSetting the Delay Mode RF Attenuation FeatureLockout in Manual Mode Lockout in Scanning ModeChannel Lockout Restoring a Locked-out Channel Restoring All Locked-out ChannelsPriority Scan Changing the Priority Channel Searching Setting a Search RangeSearch Hold Feature Data SkipFrequency Skip Auto Storing Storing Search FrequenciesSquelch SQ Mode For example, the scanner shows the following displays Additional Menu Options for SearchingService Search Skip Service SearchTrunked Systems Programming Trunking Frequencies Programming and Receiving Trunked SystemsSelecting Trunking System Type Selecting Trunking Programming Menu ModeTrunked Search Receiving Trunked SystemsID Lockout ID Hold and Direct Entry ID Hold ModeRestoring Locked-out IDs Channel Activity IndicatorsTo unlock a single ID, follow these steps To unlock all locked out IDs in a bank at onceScan Lists Programming ID Scan Lists ManuallyTo enter a Type I ID Program ID Manually with the Menu Mode To enter an Edacs IDTo enter a LTR ID ID Scan Mode Programming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Moving between Scan List MemoriesMotorola Type Call Motorola/EDACSMulti-Track Calls in Scan and Manual ModeScan & Search Icons Edacs Tracking Edacs ReceptionAn Edacs Trunked system AFS Partial Entry Feature Special Edacs FeaturesLTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionSelecting Preset Fleet Map Fleet Map ProgrammingProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Start Remote Mode Remote PC Control ModeRemote Interface To connect Scanner to PCPC Control Parameter Clone ModeChange Transfer Speed To connect the scanner to scannerComplete displays Dimmer Additional FeaturesEnter Lock Key Beep OptionReceiving Mode Selection Reverse ModeFrequency and Channel Tuning with the VFO Control Mute On/OffCare and Maintenance Troubleshooting Page VHF TV SpecificationsGlossary of terms Glossary of TermsPage Appendix Preset Fleet MapsS11 S12 Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts Service Division One Year Limited WarrantyUBZZ01305AZ