TRUNK SEARCH: This mode works similarly to TRUNK SCAN. If the scanner finds any (non-locked-out) ID when it checks the control channel, you will hear it. You will then hear any replies that follow within two seconds (or whatever delay you may have set). After that the scanner will move on and not continuously search the system for additional IDs (on busy systems you would never leave the system if this were the case). Note that if you press the SRCH key while monitoring one ID, the radio will check if any other IDs are active (it will disregard the ID you just left), and if none are active, it will move on.

LIMIT/ KEY: If you wish to exit a trunked system without waiting for the currently active talkgroup to finish its communication, press the LIMIT/key. This is particularly helpful on very busy systems where many talkgroups are active and activity is frequent and long- lasting. Pressing this key will move the scanner on to the conventional frequencies in the same bank or the next bank.

SCAN & SEARCH Icons

For the first time on a Uniden scanner, you will see both the SCAN and the SEARCH icons active at the same time. This indicates that the radio is scanning conventional banks and Trunk searching trunking banks. When the radio is trunking, only the SEARCH icon will be lit. Note that to start a conventional search, you must place the radio into conventional manual mode and then press the SEARCH key.

44

Image 54
Contents UBC780XLT Introduction Important NoticeFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Included with Your Scanner Package Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Desktop Installation Applying Power Using Standard AC PowerConnecting an External Speaker Connecting the Tape Recorder Connecting an EarphoneConnecting the Clone Cable Listening SafelySetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SCREEN Mask0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Programming Storing Frequencies into ChannelsAssigning a Bank Tag to a Bank Duplicate Frequency AlertStoring Text Tags Assigning a Text Tag to a ChannelDeleting a Stored Frequency Beep AlertProgramming Tips Assigning the beep alert to a channelTo directly access a specific channel ScanningRF Attenuation Feature Setting the Delay ModeLockout in Manual Mode Lockout in Scanning ModeChannel Lockout Restoring a Locked-out Channel Restoring All Locked-out ChannelsPriority Scan Changing the Priority Channel Setting a Search Range SearchingSearch Hold Feature Data SkipFrequency Skip Storing Search Frequencies Auto StoringSquelch SQ Mode Additional Menu Options for Searching For example, the scanner shows the following displaysService Search Service Search SkipTrunked Systems Programming and Receiving Trunked Systems Programming Trunking FrequenciesSelecting Trunking Programming Menu Mode Selecting Trunking System TypeReceiving Trunked Systems Trunked SearchID Hold and Direct Entry ID Hold Mode ID LockoutTo unlock a single ID, follow these steps Channel Activity IndicatorsRestoring Locked-out IDs To unlock all locked out IDs in a bank at onceScan Lists Programming ID Scan Lists ManuallyTo enter a Type I ID Program ID Manually with the Menu Mode To enter an Edacs IDTo enter a LTR ID ID Scan Mode Deleting a Stored ID Setting Priority in Trunking Mode Programming Scan Lists During Search Moving between Scan List MemoriesCall Motorola/EDACS Motorola TypeCalls in Scan and Manual Mode Multi-TrackScan & Search Icons Edacs Reception Edacs TrackingAn Edacs Trunked system Special Edacs Features AFS Partial Entry FeatureLTR Reception LTR TrackingMotorola Reception Motorola TrackingSelecting Preset Fleet Map Fleet Map ProgrammingProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Remote Interface Remote PC Control ModeStart Remote Mode To connect Scanner to PCChange Transfer Speed Clone ModePC Control Parameter To connect the scanner to scannerComplete displays Enter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Mute On/OffCare and Maintenance Troubleshooting Page Specifications VHF TVGlossary of Terms Glossary of termsPage Preset Fleet Maps AppendixS11 S12 User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts One Year Limited Warranty Service DivisionUBZZ01305AZ