10:EDACS ID FORM (EDCS)

You can change to display the talkgroups in decimal mode, but this mode does not provide you with nearly the flexibility that you get with AFS. The UBC780XLT defaults to show the talkgroup number in AFS mode (Agency-Fleet-Subfleet). For details on AFS see pages 46.

11:END CODE (MOTOROLA)

When this function is disabled, the radio looks for squelch before returning to the control channel instead of waiting for the disconnect tone. Only in rare instances will you need to adjust the default settings.

The condition to return to control channels depends on whether signal is present or not.

12:CONTROL CH ONLY (MOTOROLA 800 & 900 SYSTEMS)

With this mode you will be able to track Motorola Type I and II 800 and 900 MHz trunked systems by simply entering the control channel which manages the trunked system. You will not have to program the voice channels. There are 4 channel plans which you can select from.

4:SEARCH EVENT

You can program up to 10 search ranges (one per bank). The first time you program a range for a bank you will need to do so through the Menu. After the first time you can program a range as you do on most any other scanner, using the numeric keypad and the /HOLD or /LIMIT keys.

1:SEARCH BANK

Use this Menu item to select the search bank that you want to program. You can program banks 1 through 10, one at a time. For each of the banks, the following options can be modified.

1:EDIT RANGE

Enter the upper and lower frequency limits of the search range.

2:STEPS

You can assign a variety of step sizes to the search range. Note: The default step is usually acceptable and is listed in the front of the manual. (See inside front cover)

3:MODE

You can change the default receive mode with this menu item.

4:ALPHA TAG

You can alpha tag any or all of the search banks.

2:DELAY

Set a delay for the search ranges. This applies to all ranges (See CHANNEL DATA- STEPS for details).

3:ATTENUATOR

Set attenuation for all search ranges. (See CHANNEL DATA-ATTENUATOR for details).

4:TONE DATA

The default mode is off. This means that you will receive all transmissions on any frequencies that are active within your search range(s). By selecting CTCSS or DCS you can set the radio to receive only a particular subaudible tone to be

16

Image 26
Contents UBC780XLT Introduction Important NoticeFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Included with Your Scanner Package Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Connecting an External Speaker Desktop InstallationApplying Power Using Standard AC Power Connecting the Tape Recorder Connecting an EarphoneConnecting the Clone Cable Listening SafelyTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SCREEN Mask 0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Programming Storing Frequencies into ChannelsAssigning a Bank Tag to a Bank Duplicate Frequency AlertStoring Text Tags Assigning a Text Tag to a ChannelDeleting a Stored Frequency Beep AlertProgramming Tips Assigning the beep alert to a channelTo directly access a specific channel ScanningRF Attenuation Feature Setting the Delay ModeChannel Lockout Lockout in Manual ModeLockout in Scanning Mode Priority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels Changing the Priority Channel Setting a Search Range SearchingFrequency Skip Search Hold FeatureData Skip Storing Search Frequencies Auto StoringSquelch SQ Mode Additional Menu Options for Searching For example, the scanner shows the following displaysService Search Service Search SkipTrunked Systems Programming and Receiving Trunked Systems Programming Trunking FrequenciesSelecting Trunking Programming Menu Mode Selecting Trunking System TypeReceiving Trunked Systems Trunked SearchID Hold and Direct Entry ID Hold Mode ID LockoutTo unlock a single ID, follow these steps Channel Activity IndicatorsRestoring Locked-out IDs To unlock all locked out IDs in a bank at onceTo enter a Type I ID Scan ListsProgramming ID Scan Lists Manually To enter a LTR ID Program ID Manually with the Menu ModeTo enter an Edacs ID ID Scan Mode Deleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Moving between Scan List MemoriesCall Motorola/EDACS Motorola TypeCalls in Scan and Manual Mode Multi-TrackScan & Search Icons Edacs Reception Edacs TrackingAn Edacs Trunked system Special Edacs Features AFS Partial Entry FeatureLTR Reception LTR TrackingMotorola Reception Motorola TrackingProgramming a Fleet Map Selecting Preset Fleet MapFleet Map Programming Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Remote Interface Remote PC Control ModeStart Remote Mode To connect Scanner to PCChange Transfer Speed Clone ModePC Control Parameter To connect the scanner to scannerComplete displays Enter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Mute On/OffCare and Maintenance Troubleshooting Page Specifications VHF TVGlossary of Terms Glossary of termsPage Preset Fleet Maps AppendixS11 S12 User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts One Year Limited Warranty Service DivisionUBZZ01305AZ