Uniden UBC780XLT manual Menu Description and Numeric Keypad Equivalents, 2SCREEN Mask

Page 22

Menu Description and Numeric Keypad Equivalents

Below are the menu screens and a brief description or purpose of the feature.

1:SYSTEM DATA

1:DIMMER

Allows you to change the brightness of the display.

2:SCREEN MASK

Screen Mask allows you to limit what appears on the display to the alpha tags that you have set for a channel along with a few function icons. Screen Mask removes the frequency, receiving mode, tone data, signal strength bars, and the trunking repeater activity indicators. This mode is particularly useful in public safety vehicles where “information overload” is already a problem. Screen Mask does not work in Search mode.

3:KEY BEEP

Use this function to turn off the keypad acknowledgement beep. The default setting is on.

4:ENTER LOCK

Use Enter Lock to prevent accidental re-programming of channels and talkgroups entered into memory. The default setting is off.

5:PC CONTROL

Use this function to set the transfer speed (baud rate) at which your personal computer (PC) communicates with the scanner when downloading information into your scanner using the third party software. See page 55 for details.

6:CLONE

You can clone all the programming, including frequencies, talkgroups and alpha tags as well as bank settings and other parameters from one UBC780XLT to another.

7:SMART SCAN

Not applicable.

8:DATA SKIP

A scanner will normally stop on any transmission it receives. This means the UBC780XLT will occasionally stop on data signals and unmodulated transmissions. You can automatically skip many of these types of transmissions during search.

9:SQUELCH MODE

The Squelch Mode allows you to set, at your option, whether the scanner will stop on all active transmissions on a particular frequency or it will only respond to transmissions with a pre-set sub-audible tone. This applies to both conventional search and scan modes.The options are as follows:

1.CSQ - The default setting is CSQ (carrier squelch). In this mode the scanner will stop on any transmission on a programmed frequency (Squelch mode does not apply to trunking).

2.Tone SQ - In Tone Squelch mode, if you have set a subaudible tone (CTCSS or DCS) for a frequency, the scanner will only stop on that frequency if the transmission includes the prescribed tone.

12

Image 22
Contents UBC780XLT Introduction Important NoticeFront View and Display Rear View UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts UBC780XLT Flow Charts Contents Page What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Included with Your Scanner Package Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Applying Power Using Standard AC Power Desktop InstallationConnecting an External Speaker Connecting the Tape Recorder Connecting an EarphoneConnecting the Clone Cable Listening SafelyBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents 2SCREEN Mask0BANK TAG 6STEPS 5PROGRAM ID 1EDIT Range 5RECORD Programming Storing Frequencies into ChannelsAssigning a Bank Tag to a Bank Duplicate Frequency AlertStoring Text Tags Assigning a Text Tag to a ChannelDeleting a Stored Frequency Beep AlertProgramming Tips Assigning the beep alert to a channelTo directly access a specific channel ScanningRF Attenuation Feature Setting the Delay ModeLockout in Scanning Mode Lockout in Manual ModeChannel Lockout Restoring All Locked-out Channels Restoring a Locked-out ChannelPriority Scan Changing the Priority Channel Setting a Search Range SearchingData Skip Search Hold FeatureFrequency Skip Storing Search Frequencies Auto StoringSquelch SQ Mode Additional Menu Options for Searching For example, the scanner shows the following displaysService Search Service Search SkipTrunked Systems Programming and Receiving Trunked Systems Programming Trunking FrequenciesSelecting Trunking Programming Menu Mode Selecting Trunking System TypeReceiving Trunked Systems Trunked SearchID Hold and Direct Entry ID Hold Mode ID LockoutTo unlock a single ID, follow these steps Channel Activity IndicatorsRestoring Locked-out IDs To unlock all locked out IDs in a bank at onceProgramming ID Scan Lists Manually Scan ListsTo enter a Type I ID To enter an Edacs ID Program ID Manually with the Menu ModeTo enter a LTR ID ID Scan Mode Deleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Moving between Scan List MemoriesCall Motorola/EDACS Motorola TypeCalls in Scan and Manual Mode Multi-TrackScan & Search Icons Edacs Reception Edacs TrackingAn Edacs Trunked system Special Edacs Features AFS Partial Entry FeatureLTR Reception LTR TrackingMotorola Reception Motorola TrackingFleet Map Programming Selecting Preset Fleet MapProgramming a Fleet Map Programming a Hybrid System Toggling the Status Bit Control Channel Only Mode Disconnect Tone Detect Option End Code Remote Interface Remote PC Control ModeStart Remote Mode To connect Scanner to PCChange Transfer Speed Clone ModePC Control Parameter To connect the scanner to scannerComplete displays Enter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Mute On/OffCare and Maintenance Troubleshooting Page Specifications VHF TVGlossary of Terms Glossary of termsPage Preset Fleet Maps AppendixS11 S12 User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsAustralian Reverse Frequency List Ctcss Frequency List Hz DCS Tone Code Memo Memo Memo UBC780XLT Shortcuts UBC780XLT Flow Charts Page UBC780XLT Flow Charts Page UBC780XLT Shortcuts One Year Limited Warranty Service DivisionUBZZ01305AZ