Indicators
There are two indicators on the front of the projector which give information about the operating condition of the projector. These indicators illuminate or flash to warn you about problems that have occurred inside the projector, so if you notice that one of the indicators is on, turn off the power and check the table below for the cause of the problem.
LAMP indicator
TEMP indicator
Indicator name Indicator display | Problem |
The internal projector temperature is too
Illuminated (red) high.
TEMP indicator
Possible cause | Remedy |
The ventilation holes Uncover the ventilation holes. may be covered.
The ambient | Set up the projector in a place |
temperature in the | where the temperature is between |
place of use may | 41°F (5°C) and 104°F (40°C) |
be too high. | and the humidity is between 10% |
| and 80% (with no condensation). |
|
| The metal halide lamp | The air filter may | Turn off the main power |
TEMP |
| has turned off | be blocked. | supply by following the |
| automatically because |
| procedure on page 11, and | |
|
|
| ||
| Flashing (red) | the internal |
| then clean the air filter (refer |
|
| temperature has risen |
| to page 39). |
|
| to an abnormally high |
|
|
|
| level. |
|
|
|
| It is nearly time to | Does “LAMP” | This occurs when the operation |
|
| replace the lamp | appear on the | time for the lamp unit is nearing |
| Illuminated (red) | unit. | screen after the | 2,800 hours. Ask your dealer or |
|
|
| projector is turned | an Authorized Service Center |
|
|
| on? | to replace the lamp unit. |
LAMP indicator |
| The metal halide | The power may | Wait for a while until the lamp |
|
| lamp switches off | have been turned on unit cools down before | |
|
| automatically. | immediately after it | turning the power back on |
| Flashing (red) |
| was turned off. | again. |
LAMP |
| There may be an | Turn off the main power supply | |
|
| |||
|
|
| ||
|
|
| abnormality in the | by following the procedure on |
|
|
| lamp circuit. | page 11, and then contact an |
|
|
|
| Authorized Service Center. |
NOTE:
Be sure to turn off the main power by following the procedure given in “Turning the power on and off” on page 11 before carrying out any of the procedures in the “Remedy” column.
If the main power turns off after the TEMP indicator starts flashing, it means that an abnormality has occurred. Please contact an Authorized Service Center so that the necessary repairs can be made.