Nortel Networks P0605618, 555-7101-217 manual Supported peripheral devices, Modem for new systems

Page 24

1001rp server description

Standard 1.0

Supported peripheral devices

Introduction

This section identifies external devices that are supported by the 1001rp server. The following table describes the supported peripheral devices:

Device

Description

 

 

Modem

A 56 Kbps external modem (NTRH9078) provides

 

remote access to the 1001rp server. The modem connects

 

to the RS-232 COM1 connector on the rear of the server.

 

Since the modem is an external device, it requires its own

 

AC power source.The 33.6 Kbps modem (NTRH9016) is

 

also supported, but has been replaced by the 56 Kbps

 

modem for new systems.

 

 

Ethernet hub

A 10BaseT Ethernet hub provides the ELAN connection

 

between the 1001rp server and the Meridian 1 switch or

 

Succession CSE 1000 system. The customer can supply

 

a hub from third-party vendors or purchase the 3Com

 

10BaseT Ethernet hub (NTRH9017) from Nortel

 

Networks.

 

Since the hub is an external device, it requires an AC

 

power source.

 

 

 

Monitor, keyboard,

Ñ

14" monitor: NTRH9011

and mouse

 

Since the monitor is an external device, it requires its

 

 

 

 

own AC power source.

 

Ñ

Keyboard: NTRH9013

 

 

Mouse: NTRH9014

 

 

 

24

CallPilot

Image 24
Contents CallPilot P0605618 CallPilot Page Publication history Publication history Contents Installing the server and connecting the peripheral DevicesIndex 1001rp server description A p t e rServer features Server dimensions and weightIntroduction 49.5 cm 19.5Front panel features front view without the front bezel Alarm boardRear panel diagram Overhead view of empty server showing PCI and ISA connectors Slot assignments Slot definition and slot numbering1001rp slot assignments Single Board Computer Slot Reserved for COM1 COM2 I/O bracket SlotElan Network card Slot Clan Network card Slot 12bBRD20 IRQ mapping table IRQ Network connectivity Sample network setup Meridian Customer LAN optional Sample network setup Succession CSE Telephony LAN/Customer LAN 10/100BaseT or 100BaseTSwitch connectivity CallPilot Elan and Clan network setupRemote access connectivity Network requirementsSupported peripheral devices Modem Kbps external modem NTRH9078 providesSince the modem is an external device, it requires its own Also supported, but has been replaced by the 56 KbpsPreparing for installation Installation overview Installation checklistMay 2003Preparing for installation Conventions for warnings Follow this procedure to unpack the server and peripherals Unpacking the 1001rp serverTo unpack the equipment What’s next? Removing the front bezel and server cover About the front bezel doorsTo remove the front bezel To remove the server cover High current inside the chassis can cause severe injuryContinue with Inspecting the server interior on To replace the front bezel after installation is complete Inspecting the server interior To inspect the server interiorPreparing for installationStandard Power supply installation Safety precautions Safety informationEquipment handling guidelines Section a Installing the power supply modules AC or DC Installing the second power supply module AC or DC About the power supply moduleAC versus DC systems Power supply modules To install the power supply module Do one of the followingSection B Setting up DC power source for a 1001rp DC server DC wire gauge tables Metric wire conversion Following diagram shows typical rack power cabling DC rack cabling48VDC power distribution rationale About the Power Distribution Unit Multiple PDUsPDU terminal blocks and wiring diagram DC power inputBringing power and ground into the PDU To bring DC power and ground into the PDUMay Power supply installation Installing the server and connecting the peripheral devices Installing the server To install the serverPreparing the modem Required equipmentModem DIP switches DIPTo set the modem DIP switches OFF The modem sends a CD signal when it OFF Loads Y or Y1 configuration fromAT command set recognition OFF Disables command recognition dumbConnecting peripherals to the server Rear panel connectionsTo connect the mouse, keyboard, and monitor to the server To connect the modem to the serverContinue with Connecting the server to the Elan on Connecting the server to the Elan Media Access Control addressTo connect the server to the Elan Feature key adapter dongle. See Connecting the server to the Clan optional To connect the server to the ClanWhat’s next? Installing the Nortel Networks software feature key adapter To install the software feature key adapter For installation, you require a Phillips No screwdriverContinue with Connecting the server to power on RequirementsConnecting the server to power Before you beginCallPilot server To connect the 1001rp AC server to power To connect the 1001rp DC server to power Connect the DC power cable to the server, as shown belowTo start the server Binder Installing the server and connecting the peripheral devices Index Clan Elan May Index Index Page Product release Document release Standard Date May