MGE UPS Systems 5000 RT user manual Rear bracket system included with rail kits

Page 18

Pulsar MX

Do not install the UPS or battery module in hermetic closed environments without any exchange of air.

Follow steps 1 to 4 for rack mounting the UPS onto the rails.

The rails and the necessary mounting hardware are supplied by MGE UPS SYSTEMS.

Note for step 1: It is possible to adjust the position of both front mounting brackets.

Rear bracket system (included with rail kits)

To be used if you need to move the rack enclosure with UPS already rack-mounted inside.

2 — 4

Installation

86-87050-00 A01

Image 18
Contents Pulsar MX Page Pulsar MX Pulsar MX Contents Technical Support and Product Services Return Policy for Repair of Single Phase Products RGAIntroduction Environmental protectionImportant Safety Instructions Symbol Usage This page left blank intentionally 86-87050-00 A01 Tower Position PresentationStandard Positions Rack PositionRear Panels Pulsar MX 5000 RT Pulsar MX EXB RT TransformerAccessories for Rack Mount Display and Control PanelRack Mounting Kit Optional battery extension cable 6 ft/1.8 m Extended Battery EXBBattery Integration System Kit with Casters Battery extensions for Pulsar MX RTInstallation Unpacking and Contents CheckInternal Battery Connection Battery Start-up Installation in Tower PositionInstallation in Rack Position To adjust the display positionRear bracket system included with rail kits Communication Ports Connection to the RS232 or USB communication portConnection to the communication port by relays Required Protective Devices and Cable Cross-Sections Remote Power Off communication portInstallation of optional Communication card Recommended upstream protectionHardwire Connection of Output Power Cable to UPS Always connect the ground wire firstConnection of Extended Battery Module, UPS, and Transformer Connection to Output ReceptaclesFinal Start-Up Sequence OperationInitial Start-Up UPS Set-UpEquipment is supplied in ECO mode Normal modeECO mode Operating ModesLow battery warning Operation on Battery PowerTransfer to battery power End of backup timeUPS Shutdown When AC Present UPS Shutdown When on BatteryReturn to Normal AC Source Access to Maintenance and Personalization Data Access to MeasurementsDisplay Organization ON/OFF Settings Local SettingsOutput Settings UPS Set-UpMaintenance UPS Set-Up Using External SoftwareBattery Settings This page left blank intentionally 86-87050-00 A01 Equipment is no longer protected by the UPS TroubleshootingTroubleshooting Leds 21 Displayed details Signification CorrectionPower Module Fault Display Signification CorrectionGet free offers Life Cycle Monitoring LCMDescription LCM warning details SignificationSecure your installation power continuity Reset or disable LCMHot Swapping the Battery Sub-Module MaintenanceHot Swapping the Power Sub-Module Disconnecting the battery sub-module86-87050-00 A01 Technical specifications AppendixMGE Standard Single Phrase Warranty Technical Support and Product Services Pulsar MX Glossary Pulsar MX Page Contact MGE Scenic Avenue, Costa Mesa, California 92626 714