EPS 7000 Single Module

Carrier

The company or individual responsible for delivering goods from one location to another.

C

Common.

CB

Circuit breaker.

cm

Centimeter.

dB

Decibels.

DC

Direct current.

Conduit

A flexible or rigid tube enclosing electrical conductors.

C.S.S.

Customer Support Service.

Current rating

The maximum current that a conductor or equipment can carry reliably without damage.

dBA

Decibel Adjusted.

dBrnC

Decibel above reference noise.

DC or dc

Direct current, or voltage.

Digital Meter

The LCD display on the front panel of inverter system.

Earth ground

A ground circuit that has contact with the earth.

Electrician

Refers to an installation electrician qualified to install heavy-duty electrical components in

 

accordance with local codes and regulations. Not necessarily qualified to maintain or repair

 

electrical or electronic equipment.

FET

Field effect transistor.

Freq.

Frequency.

Frequency slew rate

The change in frequency per unit of time. Given in term of Hz per second (Hz/sec.).

GND

Ground (safety).

Hz

Hertz, frequency measurement unit, 1Hz is one cycle per second.

Input branch

 

circuit

The input circuit from the building power panel to the equipment.

Inverter

An electrical circuit that generates an AC sinewave output from a DC input.

Inverter mode

See “on-line” mode.

I

Current.

IEC

International Electrotechnical Commission.

IEEE

Institute of Electrical and Electronic Engineers.

Input branch circuit

The input circuit from the building power panel to the equipment.

Inverter

An electrical circuit that generates an AC voltage source from a DC voltage source.

IGBT

Insulated gate bipolar transistors

page g — 2

Glossary

Image 44
Contents EPS Service to qualified personnel only With installation manual, may cause harmful interference toOpening enclosures expose hazardous voltages. Always refer Louverture des cabinets expose des tensions dangereusesFor service call MGE UPS SYSTEMS, Inc Scenic Avenue Costa Mesa, CA 92626 714Warranty Service and Factory Repair CallRevision History Proprietary Rights StatementHow To Use This Manual Service personnel against safety hazards and possibleService personnel against possible equipment damage Equipment featureUPS Unit Serial Number MBP Cabinet Serial Number N t e n t EPS 7000 Single Module Operation Figures This page left blank intentionally Maintenance ScopeReference Manuals Section Descriptions IntroductionGeneral Description Specifications, Circuit Breakers and Powerflow Diagrams QF1Circuit Breaker Locations on the Maintenance Bypass Cabinet Power Flow Diagrams Normal Operation On-Battery OperationSingle Module Indicators and Controls Front Panel Alphanumeric Display Hidden Panel Cover PlateAudible alarm Front PanelTwo-line Alphanumeric Display Settings Display PushbuttonAlphanumeric Display and Controls Alphanumeric Display Pushbuttons ØOn/off Hidden Panel IndicatorsNumbered Lights LED Alphanumeric Indicators Reserved for future useTest connector Clear fault logAudible alarm reset Hidden Panel Lower PushbuttonsUsing the forced transfer functions will cause the load to Experience an interruption for a minimum of 0.8 seconds. BeCertain the load can tolerate this interruption see section Forced TransfersThis page left blank intentionally Status Screen Display General status screenSettings Selection Screen AlarmsSelect English U.S. as the display language to match Displays as presented in this manualSensor Measurements Bypass V, HzVoltage Measurements RMSCurrent Measurements Load Crest FPower Frequency Measurements Load P1 P2 P3 KVABattery Measurements Battery Measurements DisplaysLCD Messages General AlarmsSecondary Alarms Battery Cabinet Overtemp Charger OFF Inverter Shutdown Thermal Overload a Preparations Before Start-up Checks Before Start-up Start-upAutomatically start after the battery disconnect circuit Because it is standard for the UPS module to beProgrammed for automatic restart, the inverter will Breaker QF1 has been closedWith Maintenance Bypass Normal ShutdownOpening Q4S with the inverter stopped in a UPS without Without Maintenance BypassMaintenance bypass will disconnect the attached load Forced Transfer from Inverter to Bypass AC Input Uninterrupted Transfer ConditionsForced Transfer from Bypass AC Input Source to Inverter Gleichstrom zum Wechselrichter kommt gewoehnlich von der Batteriebank mit einer sehr hohen KurzschlussLeistungsfaehigkeit. Unbeabsichtigtes Schweissen und Schwere Verbrennungen koennen die Folgevon fehlerhafterLevel Description Preventive MaintenanceReplacement Parts Symbols Definition / Meaning O s s a r yIEC LCD Spdt Volts This page left blank intentionally Reorder form Scenic Avenue Costa Mesa, CA Page Page Scenic Avenue, Costa Mesa, California 92626 714 557