EPS 7000 Single Module

Q3BP

Optional maintenance bypass circuit breaker (in single-module UPS system); optional mainte-

 

nance bypass circuit breaker in MBC cabinet (in shared systems).

Q4S

Control or bypass circuit breaker (in single-module UPS systems); user-supplied bypass AC

 

input circuit breaker supplying the SSC (in shared systems).

Q5N

Optional UPS isolation circuit breaker (in single-module UPS systems); UPS module isolation

 

circuit breaker (in shared systems); optional SSC isolation circuit breaker (in MBC).

QF1

Battery disconnect circuit breaker.

Remote

 

emergency power off

A switch used for shutting down electrical equipment from a location away from the equipment.

SCR

Silicon controlled rectifier.

Security bypass (key)

Pushbutton on the hidden panel (UPS modules and SSC) allowing forced transfers and other

 

commands to be issued. The security key pushbutton must be held down while the desired

 

function is executed.

Shipping damage

Any damage done to an article while it is in transit.

SPDT

Single Pole Double Throw.

SSC

Static switch cabinet (in shared systems).

Static Transfer

An solid state switching mechanism electronically controlled to pass AC power directly from the

 

utility to an output load.

Technician

Refers to an electronic technician qualified to maintain and repair electronic equipment. Not

 

necessarily qualified to install electrical wiring.

Test connector

DB-9 type connector on the LCD panel allowing MGE UPS SYSTEMS Customer Support

 

Service technician to access programmable and diagnostic features of the system.

U

Voltage.

UF

Under frequency.

UL

Underwriters Laboratories, Inc.

UPS

Uninterruptible power system.

UV

Under voltage.

VAC

Volts of alternating current.

Vb

Battery voltage (in volts DC).

VDC

Volts of direct current.

Via

By way of.

VPC

Volts per cell, the measure of the electrical potential of a storage cell, such as a battery.

XFMR

Transformer.

page g — 4

Glossary

Image 46
Contents EPS Opening enclosures expose hazardous voltages. Always refer Service to qualified personnel onlyWith installation manual, may cause harmful interference to Louverture des cabinets expose des tensions dangereusesFor service call MGE UPS SYSTEMS, Inc Scenic Avenue Costa Mesa, CA 92626 714Revision History WarrantyService and Factory Repair Call Proprietary Rights StatementService personnel against possible equipment damage How To Use This ManualService personnel against safety hazards and possible Equipment featureUPS Unit Serial Number MBP Cabinet Serial Number N t e n t EPS 7000 Single Module Operation Figures This page left blank intentionally Reference Manuals Section Descriptions MaintenanceScope IntroductionGeneral Description Specifications, Circuit Breakers and Powerflow Diagrams QF1Circuit Breaker Locations on the Maintenance Bypass Cabinet Power Flow Diagrams Normal Operation On-Battery OperationSingle Module Indicators and Controls Front Panel Alphanumeric Display Hidden Panel Cover PlateAudible alarm Front PanelAlphanumeric Display and Controls Settings Display PushbuttonTwo-line Alphanumeric Display Alphanumeric Display Pushbuttons Numbered Lights Hidden Panel IndicatorsØOn/off LED Alphanumeric Indicators Reserved for future useAudible alarm reset Test connectorClear fault log Hidden Panel Lower PushbuttonsCertain the load can tolerate this interruption see section Using the forced transfer functions will cause the load toExperience an interruption for a minimum of 0.8 seconds. Be Forced TransfersThis page left blank intentionally Status Screen Display General status screenSelect English U.S. as the display language to match Settings Selection ScreenAlarms Displays as presented in this manualSensor Measurements Bypass V, HzVoltage Measurements RMSCurrent Measurements Load Crest FPower Frequency Measurements Load P1 P2 P3 KVABattery Measurements Battery Measurements DisplaysSecondary Alarms General AlarmsLCD Messages Battery Cabinet Overtemp Charger OFF Inverter Shutdown Thermal Overload a Preparations Before Start-up Checks Before Start-up Start-upProgrammed for automatic restart, the inverter will Automatically start after the battery disconnect circuitBecause it is standard for the UPS module to be Breaker QF1 has been closedWith Maintenance Bypass Normal ShutdownMaintenance bypass will disconnect the attached load Without Maintenance BypassOpening Q4S with the inverter stopped in a UPS without Forced Transfer from Bypass AC Input Source to Inverter Uninterrupted Transfer ConditionsForced Transfer from Inverter to Bypass AC Input Leistungsfaehigkeit. Unbeabsichtigtes Schweissen und Gleichstrom zum Wechselrichter kommt gewoehnlich von derBatteriebank mit einer sehr hohen Kurzschluss Schwere Verbrennungen koennen die Folgevon fehlerhafterReplacement Parts Preventive MaintenanceLevel Description Symbols Definition / Meaning O s s a r yIEC LCD Spdt Volts This page left blank intentionally Reorder form Scenic Avenue Costa Mesa, CA Page Page Scenic Avenue, Costa Mesa, California 92626 714 557