American Power Conversion MatrixTM UPS Electronics Unit EU, Rear View of the Electronics Unit

Page 7

3.2 Electronics Unit (EU)

Rear View of the Electronics Unit

1. Electronics Unit (EU)

The Electronics Unit contains the UPS’s microprocessor controls, inverter, battery charger, transfer and tap changing circuits, remote interfaces, and the user control and display console. The EU may be separated from the IU for service. See the manual section entitled Difficulty for instructions on removal of the EU.

2. Cooling fans

The EU cooling fans operate at two speeds depending upon mode of operation. The fans turn faster when the UPS is heavily loaded while operating on-battery. If either of the fans fail while operating on-line, the UPS will indicate an alarm condition and transfer to bypass operation. It either of the fans fail while operating on-battery, the UPS will immediately indicate an alarm condition. Initially, the UPS will continue to provide power to the load. However, when heavily loaded the UPS will eventually shut down in order to prevent the EU from overheating.

3. Battery Pack coupler

Battery Packs are connected at this coupler. A coupler clamp is installed over the coupler opening as furnished from the factory. See the manual section entitled Installation for instructions on how to lock mated couplers.

4. Accessory panel

The EU is furnished with an opening that accepts accessories that work with the UPS. Call your dealer or the factory for information on available accessories.

5. Computer interface port

See UPS Monitoring section of this manual for information on this interface port. Connect only factory supplied or authorized UPS monitoring cables to this port.

Image 7
Contents MatrixTM UPS User’s Manual American Power ConversionTable of Contents Hot Swappable Modules Emergency Power Off EPOIntroduction OverviewDisplay SafetyRemote Interfaces Isolation Unit IU Presentation5a. Nema 5-15R receptacles Rear View of the Electronics Unit Electronics Unit EURear View Battery PackReceiving Inspection InstallationProtection Strategies Moving the UPS PlacementInput Voltage Selection Module Interconnections Vac Input ConfigurationTypical installation showing mated battery couplers Emergency Power Off EPO Interface Start-Up Input Plug Incompatibility OperationModes of Operation On-battery mode Sleep ModeStandby mode On-line modeTransfer between modes of operation Bypass modeDefault screens Display and Controls OperationUPS Status menu UPS Control menuUPS Diagnostics menu Page UPS Setup Page Page UPS Tests Password protectionUPS Monitoring PowerChute SoftwareInterface Kits Computer Interface Port Difficulty Troubleshooting Chart UPS requires service Fault MessagesReplace Electronics Unit EU Battery status Replacing the Electronics Unit Replacing or Adding Battery Packs Obtaining Service Storing the UPS SpecificationsApprovals Noise and Surge IsolationEnvironment Physical10.69 13.13 15.57 18.01 Typical On-Battery Run Times11.56

MatrixTM UPS specifications

American Power Conversion (APC), a leader in power management solutions, has developed the MatrixTM Uninterruptible Power Supply (UPS) system to meet the critical power needs of data center infrastructure. The MatrixTM UPS is designed for scalability, reliability, and efficiency, making it an ideal choice for organizations requiring robust backup power systems.

One of the main features of the MatrixTM UPS is its modular design, which allows for easy configuration and scalability. Organizations can start with a basic setup and expand capacity as needed, ensuring optimal utilization of resources. The system is available in various configurations, enabling customization according to specific power and environmental requirements. This modularity also facilitates easy maintenance and upgrades without significant downtime.

The MatrixTM UPS utilizes advanced technologies, such as dual conversion and intelligent battery management. The dual conversion technology ensures that power is provided in a clean and consistent manner, free from fluctuations and disturbances. Additionally, the system features an integrated battery management system that optimizes battery performance, extends lifespan, and enhances overall efficiency.

One of the standout characteristics of the MatrixTM UPS is its energy efficiency. With a high-efficiency rating, this UPS minimizes energy consumption during operation, which significantly reduces operational costs and contributes to a lower carbon footprint. This is particularly beneficial for businesses looking to adhere to sustainability goals while maintaining reliable power supply.

Another key feature is the intuitive user interface that simplifies monitoring and control. Users can easily access real-time information on power status, battery health, and operational efficiency through a graphical LCD. Remote management capabilities enable administrators to monitor the system from any location, providing added flexibility and ensuring quick response times in case of power issues.

The MatrixTM UPS also prioritizes redundancy, with features such as N+1 architecture, ensuring that backup power is reliable even in the event of component failure. This level of redundancy is crucial for mission-critical applications where power interruptions can lead to significant operational disruptions.

In summary, the American Power Conversion MatrixTM UPS stands out with its modular design, advanced technology, high energy efficiency, and user-friendly interface. These characteristics make it a reliable solution for businesses looking to ensure continuity of operations in an increasingly power-dependent environment. With its robust capabilities, the MatrixTM UPS positions itself as a cornerstone for effective power management in data centers and beyond.