4. Battery Pack panel coupler

Additional Battery Packs are connected to this panel coupler. A coupler clamp is installed over the coupler opening as furnished from the factory. See the Installation section of this manual for instructions on how to lock mated couplers.

5. Battery Pack cables

Each Battery Pack cable is made from "welding grade" wire to withstand abrasion or crimping in rough duty applications.

6. Replace Battery indicator

The Replace Battery indicator is illuminated when the Battery Pack can no longer sustain a charge due to wear. See the Difficulty section of this manual if the indicator is lit.

7. In-line Battery Pack coupler

The in-line Battery Pack coupler connects to the UPS or to a panel coupler on another Battery Pack.

8. Battery communications cable

Each Battery Pack is supplied with a battery communications cable.

4.0Installation

4.1Receiving Inspection

Once the UPS has been removed from its shipping container, it should be inspected for damage that may have occurred while in transit. Immediately notify the carrier and place of purchase if any damage is found. The packing materials are made from recyclable materials and should be saved for reuse or disposed of properly.

4.2 Protection Strategies

This UPS provides high performance power line protection to the loads. There are, however, other potential entry points for damaging surges in information systems. These include serial ports (RS-232, RS-422, RS-485, etc.), parallel ports, telephone lines, and network connections. These other entry points must be considered in developing a comprehensive system protection strategy. Contact your dealer or call the number on the back cover of this manual for information on a complete set of related products designed to accomplish total system protection.

Sensitive information systems can be further safeguarded by following these guidelines:

νVerify that all electrical outlets are properly grounded.

νConnect information systems to a different electrical service branch than heavy motor loads like air conditioners, copiers, refrigerators, and heavy industrial machinery.

νPlug all power protection and information system equipment into the same branch where possible.

Image 9
Contents MatrixTM UPS User’s Manual American Power ConversionTable of Contents Introduction Emergency Power Off EPOOverview Hot Swappable ModulesSafety DisplayRemote Interfaces Isolation Unit IU Presentation5a. Nema 5-15R receptacles Rear View of the Electronics Unit Electronics Unit EURear View Battery PackInstallation Receiving InspectionProtection Strategies Placement Moving the UPSInput Voltage Selection Module Interconnections Vac Input ConfigurationTypical installation showing mated battery couplers Emergency Power Off EPO Interface Start-Up Operation Input Plug IncompatibilityModes of Operation Standby mode Sleep ModeOn-line mode On-battery modeDefault screens Bypass modeDisplay and Controls Operation Transfer between modes of operationUPS Status menu UPS Control menuUPS Diagnostics menu Page UPS Setup Page Page UPS Tests Password protectionPowerChute Software UPS MonitoringInterface Kits Computer Interface Port Difficulty Troubleshooting Chart Fault Messages UPS requires serviceReplace Electronics Unit EU Battery status Replacing the Electronics Unit Replacing or Adding Battery Packs Obtaining Service Storing the UPS SpecificationsEnvironment Noise and Surge IsolationPhysical Approvals10.69 13.13 15.57 18.01 Typical On-Battery Run Times11.56

MatrixTM UPS specifications

American Power Conversion (APC), a leader in power management solutions, has developed the MatrixTM Uninterruptible Power Supply (UPS) system to meet the critical power needs of data center infrastructure. The MatrixTM UPS is designed for scalability, reliability, and efficiency, making it an ideal choice for organizations requiring robust backup power systems.

One of the main features of the MatrixTM UPS is its modular design, which allows for easy configuration and scalability. Organizations can start with a basic setup and expand capacity as needed, ensuring optimal utilization of resources. The system is available in various configurations, enabling customization according to specific power and environmental requirements. This modularity also facilitates easy maintenance and upgrades without significant downtime.

The MatrixTM UPS utilizes advanced technologies, such as dual conversion and intelligent battery management. The dual conversion technology ensures that power is provided in a clean and consistent manner, free from fluctuations and disturbances. Additionally, the system features an integrated battery management system that optimizes battery performance, extends lifespan, and enhances overall efficiency.

One of the standout characteristics of the MatrixTM UPS is its energy efficiency. With a high-efficiency rating, this UPS minimizes energy consumption during operation, which significantly reduces operational costs and contributes to a lower carbon footprint. This is particularly beneficial for businesses looking to adhere to sustainability goals while maintaining reliable power supply.

Another key feature is the intuitive user interface that simplifies monitoring and control. Users can easily access real-time information on power status, battery health, and operational efficiency through a graphical LCD. Remote management capabilities enable administrators to monitor the system from any location, providing added flexibility and ensuring quick response times in case of power issues.

The MatrixTM UPS also prioritizes redundancy, with features such as N+1 architecture, ensuring that backup power is reliable even in the event of component failure. This level of redundancy is crucial for mission-critical applications where power interruptions can lead to significant operational disruptions.

In summary, the American Power Conversion MatrixTM UPS stands out with its modular design, advanced technology, high energy efficiency, and user-friendly interface. These characteristics make it a reliable solution for businesses looking to ensure continuity of operations in an increasingly power-dependent environment. With its robust capabilities, the MatrixTM UPS positions itself as a cornerstone for effective power management in data centers and beyond.