6.0UPS Monitoring

6.1Overview

A UPS system alone provides excellent protection from brief power problems. However, during an extended power outage an unattended computer system will eventually shut down due to battery capacity exhaustion. To prevent data corruption when the UPS shuts down, the computer must be informed by the UPS of impending shut down and take appropriate file-saving measures. This important function is called UPS monitoring. The UPS’s computer interface port is the means by which your UPS communicates with a computer system.

Some computer operating systems have built-in UPS monitoring. These systems require various hardware interfaces. Interface kits for all operating systems that support UPS monitoring are available from your dealer. In addition, your dealer also offers PowerChute software which enhances such built-in UPS monitoring. Versions of PowerChute are available which add the UPS monitoring function to the many operating systems which do not inherently provide UPS monitoring.

6.2 Interface Kits

A series of interface kits is available for operating systems that provide UPS monitoring. Each interface kit includes the special interface cable required to convert status signals from the UPS into signals which individual operating systems recognize. Each kit includes all necessary installation instructions. Systems for which interface kits are offered include Novell, LAN Manager, LANtastic, Banyan VINES and IBM AS/400.

6.3 PowerChute Software

PowerChute software provides complete data protection for most operating systems. This software is a background process that monitors the UPS through a RS-232 serial port on the host. PowerChute offers user notification of impending shutdown, power event logging, auto-restart upon power return and UPS battery conservation features. For selected operating systems, PowerChute offers sophisticated power diagnostic and network power management features. These include interactive battery testing; scheduled server shutdowns, reboots and battery testing; detailed power quality logging and a remote, real time, graphical power status display showing UPS loading and battery conditions. PowerChute is available for many platforms including Novell, OS/2, AppleShare, XENIX, most UNIX-based operating systems, and DEC VAX/VMS.

Caution: Use only factory supplied or authorized UPS monitoring cables!

Image 25 Contents
MatrixTM UPS User’s Manual American Power ConversionTable of Contents Introduction Emergency Power Off EPOOverview Hot Swappable ModulesDisplay SafetyRemote Interfaces Isolation Unit IU Presentation5a. Nema 5-15R receptacles Rear View of the Electronics Unit Electronics Unit EURear View Battery PackReceiving Inspection InstallationProtection Strategies Moving the UPS PlacementInput Voltage Selection Module Interconnections Vac Input ConfigurationTypical installation showing mated battery couplers Emergency Power Off EPO Interface Start-Up Input Plug Incompatibility OperationModes of Operation Standby mode Sleep ModeOn-line mode On-battery modeDefault screens Bypass modeDisplay and Controls Operation Transfer between modes of operationUPS Status menu UPS Control menuUPS Diagnostics menu Page UPS Setup Page Page UPS Tests Password protectionUPS Monitoring PowerChute SoftwareInterface Kits Computer Interface Port Difficulty Troubleshooting Chart UPS requires service Fault MessagesReplace Electronics Unit EU Battery status Replacing the Electronics Unit Replacing or Adding Battery Packs Obtaining Service Storing the UPS SpecificationsEnvironment Noise and Surge IsolationPhysical Approvals10.69 13.13 15.57 18.01 Typical On-Battery Run Times11.56