2. PRINTER SETUP

ENGLISH VERSION EO1-33048

2.7 Setting an Operating Environment

2.7.2 Parameter Setting (Cont.)

„ Serial (RS-232C) Interface

The following parameters of the RS-232C interface can be set:

 

Baud rate

 

Data length

 

Stop bit

 

Parity

 

Flow control

 

Set these in accordance with the setting of your host computer.

<Reference>

Properties screen of Serial (COM) under Windows98

NOTES:

1. Choose a desired baud rate by

using the [RESTART] or

[FEED] key.

port

(1) Baud Rate

This parameter is to choose a communication speed of the RS-232C interface.

As “9600 bps” has been chosen as default, change it in accordance with your PC.

2. Be careful if the printer is

turned off without pressing the

[PAUSE] key, the selected

value does not become effective.

[RESTART]

<2>PARAMETER SET SPEED 9600bps

SPEED 115200 bps

SPEED 38400 bps

SPEED 19200 bps

SPEED 9600 bps

[FEED]

 

SPEED

4800 bps

 

 

 

 

 

 

 

 

 

 

 

 

 

SPEED

2400 bps

 

 

 

 

 

After making a choice, press the [PAUSE] key.

E2-19

Image 32
Contents SA4TP Series CE Compliance for EU only VorsichtSA4TP Series Waste Recycling information for users Safety Summary Meanings of Each SymbolPrecautions Request Regarding MaintenanceTable of Contents EA1-1 EA2-1EA3-1 EA4-1Introduction Features Product OverviewAccessories Dimensions AppearanceFront View Rear ViewOperation Panel InteriorOptions Option Name Type UsagePrinter Setup Setup FlowProcedure ReferenceExample of US Type InstallationConnecting the Power Cord Loading the Media Take out the Media Holder Ass’y from the printerRaise the Release Lever and remove the Media Holder Left Insert the Media Shaft into the core of a media rollFold the Release Lever to lock the Media Holder Left Place the Media Holder Ass’y into the printerClick Upper Sensor Upper SensorLever Ass’y Setting the Feed Gap Sensor position Setting the Black Mark Sensor position Batch mode Strip mode OptionPress down the Release Bar to open the Strip Unit Tag paper or Thick paper Cut mode OptionLabel or Thin media Loading the Ribbon Open the Ribbon Cover Cont Gently close the Top Cover until it clicksConnecting the Printer to Your Host Computer Turning the Printer Refer to the B-SA4T Series Key Operation Refer to .3 ResetFine Adjustment SA4T How to Enter the System ModeParameter Setting Baud rate selection „ Serial RS-232C Interface Baud RateParity „ Serial RS-232C Interface Data LengthStop Bit Flow Control „ LCD Message LanguageREADY/BUSY XON/XOFF„ Web Printer Function when using TCP/IP LAN „ Parallel Centronics Interface„ Plug & Play IP Address Setting TCP/IP IP Address Setting This section, how to set the IP address is describedPress the Pause key to enter the IP Address Setting Mode TCP/IPPrinter IP Address This parameter is to set an IP addressGateway IP Address This parameter is to set a Gateway IP addressSubnet Mask This parameter is to set a Subnet MaskDhcp This parameter is to enable DhcpSocket Port Ascii code and Hex. code correspondence table Dhcp Client IDThis parameter is to set a Dhcp client ID General Description Installing the Printer DriversIntroduction Installing the Printer Driver Parallel InterfaceWindows 95/98/Me Windows NT4.0 Windows 2000/XP USB Interface Windows 98/MeE2-36 E2-37 E2-38 Finish button E2-40 E2-41 E2-42 Uninstalling the Printer Driver Adding/Deleting a LAN Port Adding a LAN Port Windows 95/98/MEWindows NT4.0/2000/XP Deleting a LAN PortPrinter Driver Upgrades OthersUsing the Printer Driver Print Method AdjustmentPrint Test When using an optional Cutter Module or Strip Module Position and Print Tone Fine Adjustment 3ADJUST SETFeed Amount Fine Adjustment Cut/Strip Position Fine AdjustmentReverse Feed Amount Fine Adjustment Coordinate Fine AdjustmentTone Fine When setting +0.0 mmPosition and Print Example of Cut Position Fine Adjustment Example of Strip Position Fine Adjustment Example of Reverse Feed Amount Fine Adjustment When setting -50.0 mm When setting +50.0 mmPrint Tone Fine Adjustment Ribbon Motor Voltage Fine Adjustment Threshold Setting Sensor type is displayedSelect the sensor to be adjusted by using the Feed key Press the Pause key to enter the Sensor Adjustment Mode Feed and Pause keys„ When using the Black Mark Sensor „ When using the Feed Gap Sensor „ Manual Threshold Setting „ Storing a No Media Level VoltageBlack Mark Sensor Feed Gap Sensor On Line Operation Operation PanelUsed to stop printing temporarily Used to restart printingPress and hold the Restart key for 3 seconds or longer ResetOperation Print Head/Platen/ Sensors MaintenanceCleaning Print Head/Platen/ Sensors Covers and Panels Same way, clean the outside of the Cutter Blade Optional Cutter Module 1. Open the Front CoverBacking Paper Feed Roller Strip Roller Guide Roller Restart key TroubleshootingError Messages Error Messages Problems/Cause Possible Problems Possible Problems Causes SolutionsRemoving Jammed Media Do not use any tool that may damage the Print HeadModel Printer SpecificationsThis section describes the printer specifications Mail 4STATE Customer CODE, RSS14 Supply Specifications MediaMedia Type LabelTag paper with square holes Detection Area of the Transmissive SensorLabel Detection Area of the Reflective Sensor Effective Print AreaMedia type Description RibbonRecommended Media and Ribbon Types Care/Handling of Media and Ribbon Ribbon type DescriptionCombination of Media and Ribbon Media type Vellum paper and labelROM Symbols in the messageAppendix 1 Messages and Leds When the Dhcp function is enabled Base LAN Board is being initialisedDhcp client is being initialized Printer did not succeed in writing dataFollowing message appears Appendix 2 Interface Parallel interface CentronicsConnector PINIEEE802.3 10BASE-T/100BASE-TX SA704-RFID-U1-US Awid MPR-1510A-RMSA704-RFID-U1-EU Awid MPR-1580A-RMWireless LAN Option SnmpAt least, 125% of the rated current of the product Appendix 3 Power CordWhen purchasing the power cord Appendix 4 Print Samples Appendix 4 Print Samples Interleaved 2 JAN13, EAN13EAN13+2 digits EAN13+5 digitsUPC-A+5 digits Industrial 2Customer bar code KIX CodeAppendix 5 Glossaries USB Universal Serial Bus Device used to remove labels from the backing paperMedia and ribbon Index Index EO1-33048