Toshiba TOSNIC-7000S Do not open the rear door, Accordance with customer stipulations

Page 6

6 F 3 H 1 0 0 1

2.Safety Precautions (continued)

WARNING

Do not open the rear door.

The parts inside carry high voltage. Touching them may result in electric shock, burns or failure.

PROHIBITED

CAUTION

Operators should be qualified* personnel.

Operation of the UPS by unqualified or untrained personnel may result in electric shock, injury or failure.

*In accordance with customer stipulations

MANDATORY

Make sure the air vents on the front and top of the unit are not blocked.

Blocking the vents will cause the temperature inside the unit to rise and may result in fire or unit failure.

PROHIBITED

Make sure you understand the meaning of the warning labels on the equipment, and follow the precautions indicated.

Operating the equipment with an inadequate understanding of these matters may result in electric shock or burns.

See Page 6 for the location of these warning labels.

MANDATORY

- 5 -

Image 6
Contents July 3 H 1 0 0ALL Rights Reserved Procedure and the status of the UPS unit Vent type stand-alone lead storage batterySealed stand-alone lead storage battery Synchronized modeSafety Precautions IntroductionExact nature of what must be done is indicated 3 H 1 0 0 Safety Precautions UseCards Do not open the rear door Accordance with customer stipulationsLocations of the Warning Labels Example 300 kVA Be always Do not turn off Turn on RunningDo not touch rotating section Handling Precautions 3 H 1 0 0 Handling Precautions 3 H 1 0 0 Handling Precautions Contents Appearance Example 300 kVAExample 300 kVA C52R D72B E52R F52M G52L H8A I6CH Controls and Circuit ConfigurationPanel Controls This may result in failureCircuit Configuration Fault UPS3 H 1 0 0 Panel Key-switch Key-switch Function Name RemarksPanel Keys Key Functions For HS or AHH individual battery systems Name Function RemarksPanels Graphic Display Panel2 Graphic Display Panel Control This LED is unlit when the converter has stopped This LED lights up when the UPS is operatingThis LED lights up when the AC input circuit breaker Operating. It blinks when the converter is starting upLCD Display Scroll up Scroll down200V 3 H 1 0 0 Normal Display ScreenNormal Display Screen LCD Screen Description 50 %BYP I/P-V Normal Display Screen60.0Hz 401V52R Trip 3 H 1 0 0 Failure Display ScreenFailure Display Screen LCD Screen Description 98-09-093 H 1 0 0 LCD Screen Switching Operation Operation General Description/Objective Types of OperationPre-operational check Startup Starts up and operates the stopped UPSProcedures StartupMain circuit AC input Circuit breaker 52R When the message Appears, turn onBypass Press ‘RUN’ Switch Bypass Move #52R to ‘ON’ PositionTo finish On page 14 for at least SecondWait several seconds For the startup process Main circuit DC inputHold down the UPS Key g in the Figure → The will start Power supply Changing processUPS power supply On page14 for at3 H 1 0 0 Switch Power Supply UPS → Bypass 3 H 1 0 0 3 H 1 0 0 Stop StopRestart Press ‘RUN’ Switch Shutdown Move #52R to ‘OFF’ Breaker72BBatteries LED unlit → This complete UPS Shutdown 3 H 1 0 0 Complete Shutdown Complete ShutdownTurn off the precharge Circuit switch 6CHUsing the scroll keys Wait about 20 minutes Until the DC capacitorChanging From Floating Charge to Equalized Charge Second → Change to floating Charge is complete Changing From Equalized Charge to Floating ChargeCheck to make sure That the Equal Float Charge LED lit Equal Charge LED unlitChanging from Protective Charge to Floating Charge 3 H 1 0 0 Changing the Power Supply to Maintenance Bypass Changing From UPS to maintenance Bypass Power Supply1 Startup Changing From Maintenance Bypass to UPS Power SupplySame as steps 1-4 52R 72B 52C 52M 52LTroubleshooting Types of ErrorsName Description 52R Trip 98-09-09 LCD Failure DisplaysFailure Data Screen Failure Data Screen Descriptions↑ indicates there is a warning screen before this screen Up to 10 screens of warning data can be displayedShows the nature of the warning. For details, see Section ↓ indicates there is a warning screen after this screen3 H 1 0 0 Failure Messages Protective Detector LocationsFault Trip LCD Message Description IndicationBattery temperature has risen Bypass input frequency errorIncluding operation error Battery fluid level has gone below prescribed levelFor Individual battery systems. For HS or AHH batteries Position of Scroll Keys in Failure Data ScreensScroll Keys Scrolls to the previous screen see FigureScrolls to the next screen see Figure Procedure Saving WaveformsOnly open the front panel when performing necessary Restoring UPS OperationFailure Data screens 98-09-09 By scrolling with scroll 11 Restoring UPS Operation ExampleAlso check for other Panel