Appendix A: Specifications
Model Number  | UG1A1A015C6TB 1  | UG1A1A020C6TB1  | UG1A1A024C6TB1  | UG1G2L024C6TB | ||
  | 
  | 
  | 
  | 
  | 
  | |
Rated Capacity  | 1500VA (1.05KW)  | 2000VA (1.4KW)  | 2400VA (1.68KW)  | 2300VA (1.61KW)  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | Single phase  | |
  | Input voltage  | Single phase 120VAC, +10% to   | 208/240VAC, +10%  | |||
  | to   | |||||
Input  | 
  | 
  | 
  | 
  | (125 VAC to 229VAC)  | |
Input transformer  | 
  | Isolation Transformer  | 
  | Auto Transformer  | ||
  | 
  | 
  | ||||
  | 
  | 
  | 
  | 
  | ||
  | Input frequency  | 
  | 50/60 Hz +/- 3 Hz 3  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | Input capacity 5  | 1750VA  | 2250VA  | 2650VA  | 2600VA  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | Input power factor  | 
  | Approximately unity (0.95 to 1.0)  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | Input voltage  | Single phase 120VAC, +10% to   | Single phase  | |||
Bypass | 208/240 VAC +/- 10% 4  | |||||
  | 
  | 
  | 
  | 
  | ||
Output voltage  | 
  | Single phase 120VAC  | 
  | Single phase  | ||
  | 
  | 
  | 
  | 
  | 208/240/120 VAC  | |
  | Overload rating  | 
  | 125% for 10 minutes, 150% for 5 minutes  | 
  | ||
  | Output voltage  | 
  | Single phase 120 VAC  | 
  | Single phase  | |
  | 
  | 
  | 240/208 /120 VAC  | |||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | Output transformer  | 
  | None  | 
  | Isolation Transformer  | |
  | 
  | 
  | 
  | 
  | ||
  | Output voltage regulation  | 
  | Within +/- 3%, steady state  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | Rated output current (rms)  | 12.5A  | 16.6A  | 20A  | 9.5A  | |
  | 
  | 
  | 
  | 
  | 
  | |
Output  | Maximun output current  | 31.25Apk  | 41.5Apk  | 50Apk  | 23.75Apk  | |
(peak)  | ||||||
  | ||||||
  | 
  | 
  | 
  | 
  | ||
  | 
  | 
  | 
  | 
  | 
  | |
  | Inverter overload capacity  | 
  | 125% for 60 seconds, 150% for 30 seconds  | 
  | ||
  | Crest factor  | 
  | 2.5 at full load  | 
  | ||
  | 
  | 
  | ||||
  | Output frequency  | 50/60 Hz (+/- 0.5% in free running mode, line sync range   | ||||
  | Output voltage waveform  | |||||
  | 
  | 
  | 
  | 
  | 
  | |
  | Rated load power factor  | 
  | 0.7  | 
  | 
  | |
  | 
  | 
  | 
  | 
  | 
  | |
  | Effeciency   | 80%  | 80%  | 80%  | 79%  | |
  | 
  | 
  | 
  | 
  | 
  | |
Note 1: Currently under development, unit specifications may be changed.
Note 2: Below 79% input voltage unit may begin parallel operation; supplementing input power with battery power. The point at which parallel operation begins is load dependent (for a detailed explanation of Parallel Operation see Appendix C: Parallel Operation).
Note 3: If input frequency is below 50 Hz, the input Voltage must not exceed 103% of rated input Voltage.
Note 4: In BYPASS mode if the Input voltage is below 90% or above 110%, the UPS output will be turned off. (See Appendix D: Bypass Under Voltage/Over Voltage)
Note 5: The input capacity is computed to include peak battery charging power.
38  | 1800 Series User Manual  |