Agilent Technologies E6701A manual Etsi Test Mode measurements have problems

Page 29

Parameters table to LLC Frame Check Sequence; change the table value to Corrupt.

2.2.3.It is possible that the mobile is capable but GMM is prioritised too low and the wireless appliance is unable to sustain the link.

2.2.3.1.To get around this we can change the BLER block polling period. This will allow the mobile to send the ACK/NACK less frequently(one negative result: TX measurements will be slower since the mobile is not transmitting every frame.) Go to call parameters, 1 of 4.

3.ETSI Test Mode measurements have problems:

3.1.Check that the mobile is capable of the ETSI test mode you would like to use, if not it will not work

3.2.Check the same parameters as in Attach problems.

4.If the attach condition is terminated, this may be a Connection Reconfiguration problem:

4.1.This may be a Connection Reconfiguration problem. When any of the connection parameters are reconfigured the connection is terminated.

4.2.The mobile likely does not have the PACKET_TIMESLOT_RECONFIGURE message implemented.

4.2.1.This message is used to change MSTXL, channel, Band, Coding Scheme, Multislot configuration, and offset P0.

4.2.2.The solution when using the PACKET_TIMESLOT_RECONFIGURE message is to stop the data connection before changing parameters, then restart the data connection.

4.3.Alternatively, you can change the message used to change parameters to

PACKET_DOWNLINK_ASSIGNMENT; or, for power changes use the

PACKET_POWER_AND_TIMING_ADVANCE message. Go to call parameters, 1 of 4.

5.If Internet Explorer cannot access the 8960 Welcome Page:

5.1.Connections:

5.1.1.Check that the LAN cables are good, and are properly connected

5.1.2.If you are using the Test Set’s front panel DATA port: check that the LAN jumper cable is attached on the Test Set rear panel between the LAN PORT connector and the ETHERNET TO FRONT PANEL connector. (NOTE: For minimum RF interference, Agilent recommends using the rear-panel LAN PORT connector).

5.2.Test Set:

5.2.1.On the System Config Screen, check that the Application is GPRS Lab Application.

5.2.2.The Test Set LAN IP Address and Subnet Mask should not include leading

zeros.

 

 

 

Example:

111.22.333.44 is correct

 

 

111.022.333.044 is incorrect

 

 Copyright 2002 Agilent Technologies.

10001810-E6701A Tutorial LAN Connection

All Rights Reserved.

 

Page 29 of 32

Rev. 1.2; Feb. 14, 2002

Image 29
Contents Page Table of Contents Appendix B Troubleshooting Appendix C. Glossary Appendix a Installing a WAP Gateway into a PCIntroduction About This TutorialEquipment Required for this Tutorial Normal LAN Cable Quantity Setup LAN Addresses Network SetupTest Set Setup Set the Cell and Call Parameters Set the Date and Time OptionalSet the RF In/Out Amplitude Offset Windows 98 and Static Address PC SetupWindows 98 and Dhcp Address Page Windows 2000 and Static Address Set up NetworkWindows 2000 and Dhcp Address Determine PC IP address Verify PC Settings On the WAP Settings menu, scroll to 1Primary IP Set Up Your Wireless DeviceVerify that Your Device Will Perform an Attach Motorola Timeport phone exampleSet the Device’s Primary Port On the WAP Settings menu, scroll to 2Primary PortSet Data Bearer to Gprs Set WAPlite Gateway Address in Your DeviceSetup is now complete Here are some important points about the log data Product Feature Screen Image CaptureProduct Feature Protocol Logging Save the Log to the PC View the log data on the PCView the saved log Log Data Using the Test Set’s Front PanelPinging the DUT the phone or wireless device Product Feature PingPinging an Alternate Device such as your PC on the LAN If your LAN does not use a firewall to access the Internet Product Feature Data ChannelMotorola Example Scroll to http//local/waplite.wmlMotorola Timeport Example Product Feature Additional Connection Parameters Infinite WAPLite Gateway by Captaris Inc Appendix a Installing a WAP Gateway into a PCTo download the WAPlite software To load the WAPlite software on your PCIf Bler mode measurements have problems Appendix B TroubleshootingIf the wireless device will not attach, check that If Internet Explorer cannot access the 8960 Welcome Etsi Test Mode measurements have problemsPhone won’t transmit IP datagrams in Data Channel functions Phone can’t access browse real Internet sitesBER measurement errors Page Appendix C. Glossary