Assign the Unit Name
The unit must be assigned a unique name. The unit software relies on associating unit names with ISDN numbers and IP addresses for its core functionality.
1Enter CO SYS to display the System Parameters screen.
2Type a unique name for the unit in the Unit Name field. It can have up to 12 characters but note that the name is
3Press [Ctrl]+[E] to submit the new setting and then enter SAVE
Configure the Ethernet Port
A valid, unique port IP address is required for the Ethernet port.
1Enter CO PO to display the Port Configuration screen.
2Select the LAN1 port using the Arrow keys and enter ED to display the Edit Ethernet Port screen.
3Type a valid, unique IP address for the unit in the Port IP Address field. Do not type the local network IP address.
4Press [Ctrl]+[E] to submit the new setting and then enter SAVE
Configure the ISDN Network Type
The ISDN network type parameter must be set to the correct ISDN service, otherwise connections and data transmission over
1Enter CO IS PA to display the ISDN Parameters screen.
2Toggle the Network Type field, using the Spacebar, to the correct ISDN network type as given by the service provider.
3Press [Ctrl]+[E] to submit the new setting and then enter SAVE
Configure the ISDN Numbers Table
Set up the ISDN numbers table to associate each remote unit name with an ISDN number and an IP address. Central site autocalls rely on