Action to take: Contact your Nortel service representative.
ERR: Create_screen_templates
Meaning: TRS was unable to open a screen template file or found a
syntax error in the screen template files.
Action to take: Check the screen template files. Make sure they are syntax error free, readable text files.
ERR: Create_action_templates
Meaning: TRS was unable to open an action template file or found a syntax error in the action template files.
Action to take: Check the correctness of action template files. Make sure there are no syntax errors and that they are readable text files.
ERR: Order_templates
Meaning: The screen templates referenced in the action templates were not found.
Action to take: Create the appropriate screen templates.
ERR: Load_runtime_config
Meaning: TRS was unable to load the configuration file trs.conf.
Action to take: Syntax error in trs.conf, revise it.
ERR: Check_action_template
Meaning: TRS was unable to find the reset or logout action templates defined in the header of an action template.
Action to take: Check and create the appropriate action templates.
ERR: All communication boards are not operational
Meaning: None of the communication boards is operational.
Action to take: Make sure the communication board has been downloaded correctly. The download command should be included in the .profile file.