A-2Host error messages

Action to take: Contact your Nortel service representative.

ERR: Create_screen_templates

Meaning: TRS was unable to open a screen template file or found a

syntax error in the screen template files.

Action to take: Check the screen template files. Make sure they are syntax error free, readable text files.

ERR: Create_action_templates

Meaning: TRS was unable to open an action template file or found a syntax error in the action template files.

Action to take: Check the correctness of action template files. Make sure there are no syntax errors and that they are readable text files.

ERR: Order_templates

Meaning: The screen templates referenced in the action templates were not found.

Action to take: Create the appropriate screen templates.

ERR: Load_runtime_config

Meaning: TRS was unable to load the configuration file trs.conf.

Action to take: Syntax error in trs.conf, revise it.

ERR: Check_action_template

Meaning: TRS was unable to find the reset or logout action templates defined in the header of an action template.

Action to take: Check and create the appropriate action templates.

ERR: All communication boards are not operational

Meaning: None of the communication boards is operational.

Action to take: Make sure the communication board has been downloaded correctly. The download command should be included in the .profile file.

555-9001-316 Standard 1.0 February 1996

Page 76
Image 76
Nortel Networks VT100 ERR Createscreentemplates, ERR Createactiontemplates, ERR Ordertemplates, ERR Loadruntimeconfig