A-1

Appendix A: Host error messages

Terminal Resource Server (TRS) Messages

ERR: Unable to reset application environment

Meaning: TRS was unable to reset the 3270 system.

Action to take: Stop IVR 2.0/I. Make sure the 3270 board has been downloaded correctly. The download command should be included in the .profile file.

ERR: Unable to load configuration file

Meaning: TRS was unable to load the configuration file trs.conf.

Action to take: Syntax error in trs.conf under 3270 directory, revise it.

ERR: Failed to startup VT100 Server

Meaning: TRS was unable to reset the vt100 system.

Action to take: Check the existence of the file ../vt100/vt100.ctl. Make sure its format is correct. Look at ../vt100/vt100.log to make sure that the communication ports have been opened successfully. Also make sure the communication device is properly defined.

ERR: VT100 Server startup

Meaning: VT100 Server has been started up.

Action to take: None. Notification only.

ERR: Create_3270_objects

Meaning: TRS was unable to create or initialize the session, board or process data structure.

Meridian IVR VT100 Gateway Development Guide Product release 2.0/I

Page 75
Image 75