Host error messages A-17

Action to take: Revise the application to keep the screen templates within the limit specified by xx.

ERR: Open action file xx failed

Meaning: TRS failed to open the action file xx.

Action to take: Create or change permissions of the action template file to readable.

ERR: Memory allocation failure for ACTION entry

Meaning: TRS was unable to allocate memory for the action structure.

Action to take: Contact your Nortel service representative.

ERR: Read head data from action file xx

Meaning: Syntax error in the header section of the action template file.

Action to take: Check the syntax of the header section of the action template file.

ERR: Read screen name from action file xx

Meaning: The screen name was missing from the action template file xx.

Action to take: Add appropriate screen names under the header section of the action template file.

ERR: Action xx exceeds max screen entries xxx

Meaning: There are too many screens defined in the action template file xx.

Action to take: Revise the action template file to keep the total number of

screens within the limit specified by xxx.

ERR: Screen xx of Action xxx not found

Meaning: Screen xx defined in the action template xxx was not found under the 3270 directory.

Action to take: Create the appropriate screen template file.