3-12Getting started

Baud Rate

300 to 19200. Setting the baud rate tells the TRS the rate at which it is to communicate with the host. Set the baud rate by typing B then the rate. For example B4800 or B19200.

Parity

PARENB enables parity generation and detection.

PAREVN sets parity to even.

PARODD sets parity to odd.

CSTOPB

CSTOPB select 1 stop bit per character. If CSTOPB is not specified, then there are 2 stop bits per character.

DIAL_UP

Enter DIAL_UP in the com.conf file if IVR 2.0/I is going to access the host computer via modem.

DEBUG_LEVEL

1 to 5. Setting the debug level determines how much debugging information is sent to the /u/ivr/vt100/vt100log file.

MAXIMUM_WAIT_TIME

This parameter tells the TRS how long to wait for the output from the host to end. Only use this parameter if you can not use a screen.conf file. The wait time is specified in seconds.