Page 13

AutoSense® Operation

AutoSense® is a factory installed feature requested at time of order. It provides for hands-free or handheld operation. AutoSense® is acti- vated by scanning the Enable AutoSense® symbol. The scanner will respond by emitting a continuous, low level red beam of light known as the trigger beam. AutoSense® is deactivated by scanning the Dis- able AutoSense® symbol.

When the AutoSense® feature is used with PSC’s AutoSense® stand (specifically designed for standard and HP scanners), the user must first attach the plastic scanner holder to the bracket of the stand as shown in Figure 1, next page. The scanner is then mounted into the holder. Insure that the trigger beam is aimed at the reflective tape affixed to the stand. AutoSense® is now ready to automatically scan bar code labels presented to it. When the trigger beam is broken by the bar code label, the scan beam will automatically engage and decode the bar code symbol. Any time the scan beam disappears, whether by a decode or by a scan beam timeout, the automatic trigger must be re-enabled by allowing the trigger beam to sense the reflec- tive tape.

While AutoSense® is activated, the user is able to remove the scanner from its holder and use it for handheld scanning operation. When the scanner is removed from the AutoSense® holder, the trigger beam will be broken and the scan beam will automatically be engaged. If the scanner does not decode a bar code symbol, the scanning beam will turn off after two to six seconds. Scanning is re-initiated by man- ually pulling the trigger. When the scanner is replaced into the holder AutoSense® will be automatically re-engaged when the trigger beam senses the reflective tape.

 

When the scanner is powered from a battery, such as in a

 

hand-held terminal, AutoSense® should be disabled. In a

 

battery powered application, the user is strongly recom-

 

mended to use the power conservation feature of scan-

NOTE

ner operation. Power conservation reduces power draw

from the battery between scans to extremely low levels.

 

 

AutoSense® will function only in full power mode.

06656

5

Image 13
Contents User’s / Programming Guide Disclaimer PSC IncPage Page Table of Contents Keyboard Wedge Parameters Symbologies Serial CommandsMessage Formatting Wand Emulation ParametersMemory Module IiiScanner Labeling Technical SupportUser’s / Programming Guide Introduction Cable Installation InstallationUnpacking Keyboard WedgeConnecting a Magnetic Stripe Reader Connecting the Power SupplyTerminal Power-Up Sequence Scanning Reset to Default ZA will cause the PSC scanSerial RS232 Mode Serial TTL ModeSerial Communications AutoSense Operation Scanner holder Stand base Enable AutoSense Disable AutoSenseWand Emulation Operation Enable Wedge Enable Serial ModeSame Code Wand Emulation Code Type = Same Code Wand EmulationWedge Mode Options Setup OverviewWand Emulation Options Data Synchronization Serial Communication and Wedge OptionsBaud Rate Protocol Parity Stop BitsCode Interleaved 2 Standard 2 Codabar SymbologiesCode Vice representativeParameters Selection Guidelines Beeper On Volume LowExamples User’s / Programming Guide Serial Communication Reset DefaultBaud Rate Select Serial OutputBit Options Data Stop Bits Parity Data TransmissionOdd Even Mark Space Mark Space Communications Protocol Bit, No ParityNone Inverted Serial CommunicationsCTS Disable Stop/Go Protocol Enable Stop/Go Protocol Label Buffering Enable No Read Disable No ReadNo Read Option Full Buffering No Buffering One Label BufferingEnable Parameter Messages Disable Parameter Messages Menu Commands Parameter MessagesDisable External Trigger#*@ External Trigger+ External Trigger OperationNo interlabel delay *@ Set interlabel delay 0-9.9 seconds Intercharacter DelayGeneral Parameters External TriggerSystem Status Transmission ModeDisplay Configuration Power ConsumptionEnable Continuous@ Full Power Enable Standby *# Laser RedundancyEnable 4 Times Laser Redundancy Laser TimeoutBeeper Off Beeper On Volume Low Beeper OperationMessage Formatting Beeper On Volume Medium Beeper On Volume Loud *#@Prefixes and Suffixes Programmable options do not apply in Wand Emu LationSuffix PrefixPrefix = None*# Prefix = STX Prefix = SOH Terminal ID Select Suffix = ETB NUL Suffix = CR and LFCode Identifier Characters Code IdentifierPreamble Preamble or Postamble SelectionPostamble 0,0 hexadecimalUser’s / Programming Guide General Serial Command Format Serial CommandsEnable I 2 of 5 with check digit Command FunctionBeeper Off CR-LF Ack Communication Parameter Changes Power Standby and Serial CommandsManual Scanning Interaction Keyboard Wedge Parameters Wedge Mode Enable @06656 User’s / Programming Guide Explained in Appendix a Disable UPC both a and E SymbologiesUPC a and E Disable Expanded UPC-E *#@ Enable Expanded UPC-E User’s / Programming Guide Disable UPC-E Enable transmissionof UPC-E check digitEAN/JAN Disable EAN/JAN 8 or 13 Digit #@Disable EAN-8 independently Code Disable CodeDo Not Xmit Start and STOP*#@ Transmit Start and Stop Following are only valid if CHK Char is enabledCode 2 of 5 Interleaved Disable Interleaved Code 2 of 5*#@Maximum Length I 2 of 5 specified by two digits Code 2 of 5 Standard Disable Codabar *#@ Enable Code 128 *#@Enable Codabar Minimum Length specified by two digitsMaximum Length specified by two digits Enable Transmission of START/ Stop CharacterMSI/Plessey Enable Code Standard Code 16K Enable 16K Code Disable 16K CodeDigit Selection Symbol Function Symbology Identifiers06656 Bology identifiers Programming SymbolEAN-13 Code Symbology IdentifiersStandard 2/5 Code MSI/PlesseySelect Code Type Wand Emulation ParametersBar Code Polarity Transmission RateInches per second# Data Synchronization Disable Data # Synchronization Enable Data SynchronizationActive # Polarity High Active Polarity Low Memory Module Disable Memory Module*# Enable Memory Module SetupMarker Beam Enable Marker Beam Disable Marker Beam06656 Scanner Labeling Service and WarrantyHazardous visible light exposure Cleaning MaintenanceInspection PSC Website Support PSC Website TekForum Technical SupportReseller Technical Support Telephone Technical SupportHexadecimal Conversion Table Appendix aPart a Part B Ascii HEX Function Primary Function Key TablePC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25 Secondary Function Key TablesIBM 3171/3181/3191 and IBM VT220/320/420 Apple MacIntosh 06656 User’s / Programming Guide Declaration of Conformity PSC Inc