Datalogic Scanning DS2200 SH2348, DS1100 SH2347 manual Data Synchronization

Page 68

Data Synchronization

Your PSC scanner can be prepared to synchronize the transmission of scanned data to the timing sequence some terminals require to prop- erly receive the data. This relationship is diagrammed in Figure 2.

Figure 2. Timing Sequence Diagram

Data Transmission

data

white space

(ta)

Active

(th)

Data Synchronization

Setup Time (ts) 200 ms - 220 ms

Hold Time (th) 0 ms - 10 ms

RTS output is used for the data synchronization signal. Scan XD to enable the data synchronization signal. Scan Option XC to disable Data Synchronization.

XC

Disable Data # Synchronization

XD

Enable Data Synchronization

Polarity may be selected as either active high or low by scanning XE (high) or XF (low).

60

User’s / Programming Guide

Image 68
Contents User’s / Programming Guide PSC Inc DisclaimerPage Page Table of Contents Serial Commands Keyboard Wedge Parameters SymbologiesMessage Formatting Wand Emulation ParametersIii Memory ModuleScanner Labeling Technical SupportUser’s / Programming Guide Introduction Installation Cable InstallationUnpacking Keyboard WedgeConnecting the Power Supply Connecting a Magnetic Stripe ReaderTerminal Power-Up Sequence Scanning Reset to Default ZA will cause the PSC scanSerial Communications Serial TTL ModeSerial RS232 Mode AutoSense Operation Enable AutoSense Disable AutoSense Scanner holder Stand baseEnable Wedge Enable Serial Mode Wand Emulation OperationSame Code Wand Emulation Code Type = Same Code Wand EmulationWand Emulation Options Setup OverviewWedge Mode Options Serial Communication and Wedge Options Data SynchronizationBaud Rate Protocol Parity Stop BitsSymbologies Code Interleaved 2 Standard 2 CodabarCode Vice representativeExamples Beeper On Volume LowParameters Selection Guidelines User’s / Programming Guide Reset Default Serial CommunicationBaud Rate Select Serial OutputOdd Even Mark Space Data TransmissionBit Options Data Stop Bits Parity Mark Space Bit, No Parity Communications ProtocolNone Inverted Serial CommunicationsCTS Disable Stop/Go Protocol Enable Stop/Go Protocol Enable No Read Disable No Read Label BufferingNo Read Option Full Buffering No Buffering One Label BufferingMenu Commands Parameter Messages Enable Parameter Messages Disable Parameter MessagesDisable External Trigger#*@ External Trigger+ External Trigger OperationIntercharacter Delay No interlabel delay *@ Set interlabel delay 0-9.9 secondsGeneral Parameters External TriggerTransmission Mode System StatusPower Consumption Display ConfigurationEnable Continuous@ Full Power Enable Standby *# Laser RedundancyLaser Timeout Enable 4 Times Laser RedundancyBeeper Off Beeper On Volume Low Beeper OperationBeeper On Volume Medium Beeper On Volume Loud *#@ Message FormattingPrefixes and Suffixes Programmable options do not apply in Wand Emu LationPrefix = None*# Prefix = STX Prefix = SOH PrefixSuffix Suffix = CR and LF Terminal ID Select Suffix = ETB NULCode Identifier Code Identifier CharactersPreamble or Postamble Selection PreamblePostamble 0,0 hexadecimalUser’s / Programming Guide Serial Commands General Serial Command FormatBeeper Off CR-LF Ack Command FunctionEnable I 2 of 5 with check digit Manual Scanning Interaction Power Standby and Serial CommandsCommunication Parameter Changes Wedge Mode Enable @ Keyboard Wedge Parameters06656 User’s / Programming Guide Explained in Appendix a UPC a and E SymbologiesDisable UPC both a and E Disable Expanded UPC-E *#@ Enable Expanded UPC-E User’s / Programming Guide Enable transmissionof UPC-E check digit Disable UPC-EDisable EAN/JAN 8 or 13 Digit #@ EAN/JANDisable EAN-8 independently Disable Code CodeFollowing are only valid if CHK Char is enabled Do Not Xmit Start and STOP*#@ Transmit Start and StopMaximum Length I 2 of 5 specified by two digits Disable Interleaved Code 2 of 5*#@Code 2 of 5 Interleaved Code 2 of 5 Standard Enable Code 128 *#@ Disable Codabar *#@Enable Codabar Minimum Length specified by two digitsEnable Transmission of START/ Stop Character Maximum Length specified by two digitsMSI/Plessey Enable Code Standard Code Enable 16K Code Disable 16K Code 16KDigit Selection Symbology Identifiers Symbol Function06656 Programming Symbol Bology identifiersSymbology Identifiers EAN-13 CodeStandard 2/5 Code MSI/PlesseyWand Emulation Parameters Select Code TypeBar Code Polarity Transmission RateInches per second# Disable Data # Synchronization Enable Data Synchronization Data SynchronizationActive # Polarity High Active Polarity Low Memory Module Setup Disable Memory Module*# Enable Memory ModuleEnable Marker Beam Disable Marker Beam Marker Beam06656 Hazardous visible light exposure Service and WarrantyScanner Labeling Inspection MaintenanceCleaning Technical Support PSC Website Support PSC Website TekForumReseller Technical Support Telephone Technical SupportAppendix a Hexadecimal Conversion TablePart a Part B Primary Function Key Table Ascii HEX FunctionSecondary Function Key Tables PC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25IBM 3171/3181/3191 and IBM VT220/320/420 Apple MacIntosh 06656 User’s / Programming Guide Declaration of Conformity PSC Inc