Datalogic Scanning DS1100 SH2347, DS2200 SH2348 manual Secondary Function Key Tables

Page 81

Secondary Function Key Tables

PC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25

ASCII

HEX

FUNCTION

NUL

00

ESCAPE

SOH

01

NEW LINE ENTER

STX

02

ALT left side Make

ETX

03

ALT left side Break

EOT

04

CTRL left side Make

ENQ

05

CTRL left side Break

ACK

06

ENTER right keypad (NOTE 1)

BEL

07

Cursor up (inner keypad)

BS

08

Cursor dn (inner keypad)

HT

09

Cursor left (inner keypad)

LF

0A

Cursor right (inner keypad)

VT

0B

TAB FWD

FF

0C

DEL (inner keypad)

CR

0D

NEW LINE ENTER

SO

0E

INS (inner keypad)

SI

0F

Page Up (inner keypad)

DLE

10

Page Dn (inner keypad)

DC1

11

HOME (inner keypad)

DC2

12

PRINT SCREEN

DC3

13

BACKSPACE

DC4

14

BACKFIELD (Shift TAB)

NAK

15

SCROLL LOCK

SYN

16

F1

ETB

17

F2

CAN

18

F3

EM

19

F4

SUB

1A

F5

ESC

1B

F6

FS

1C

F7

GS

1D

F8

RS

1E

F9

US

1F

10

NOTE 1: [+] right keypad for the PC/XT and IBM PS/2 Model 57/25.

06656

73

Image 81
Contents User’s / Programming Guide Disclaimer PSC IncPage Page Table of Contents Keyboard Wedge Parameters Symbologies Serial CommandsMessage Formatting Wand Emulation ParametersMemory Module IiiScanner Labeling Technical SupportUser’s / Programming Guide Introduction Cable Installation InstallationUnpacking Keyboard WedgeConnecting a Magnetic Stripe Reader Connecting the Power SupplyTerminal Power-Up Sequence Scanning Reset to Default ZA will cause the PSC scanSerial TTL Mode Serial RS232 ModeSerial Communications AutoSense Operation Scanner holder Stand base Enable AutoSense Disable AutoSenseWand Emulation Operation Enable Wedge Enable Serial ModeSame Code Wand Emulation Code Type = Same Code Wand EmulationSetup Overview Wedge Mode OptionsWand Emulation Options Data Synchronization Serial Communication and Wedge OptionsBaud Rate Protocol Parity Stop BitsCode Interleaved 2 Standard 2 Codabar SymbologiesCode Vice representativeBeeper On Volume Low Parameters Selection GuidelinesExamples User’s / Programming Guide Serial Communication Reset DefaultBaud Rate Select Serial OutputData Transmission Bit Options Data Stop Bits ParityOdd Even Mark Space Mark Space Communications Protocol Bit, No ParityNone Inverted Serial CommunicationsCTS Disable Stop/Go Protocol Enable Stop/Go Protocol Label Buffering Enable No Read Disable No ReadNo Read Option Full Buffering No Buffering One Label BufferingEnable Parameter Messages Disable Parameter Messages Menu Commands Parameter MessagesDisable External Trigger#*@ External Trigger+ External Trigger OperationNo interlabel delay *@ Set interlabel delay 0-9.9 seconds Intercharacter DelayGeneral Parameters External TriggerSystem Status Transmission ModeDisplay Configuration Power ConsumptionEnable Continuous@ Full Power Enable Standby *# Laser RedundancyEnable 4 Times Laser Redundancy Laser TimeoutBeeper Off Beeper On Volume Low Beeper OperationMessage Formatting Beeper On Volume Medium Beeper On Volume Loud *#@Prefixes and Suffixes Programmable options do not apply in Wand Emu LationPrefix SuffixPrefix = None*# Prefix = STX Prefix = SOH Terminal ID Select Suffix = ETB NUL Suffix = CR and LFCode Identifier Characters Code IdentifierPreamble Preamble or Postamble SelectionPostamble 0,0 hexadecimalUser’s / Programming Guide General Serial Command Format Serial CommandsCommand Function Enable I 2 of 5 with check digitBeeper Off CR-LF Ack Power Standby and Serial Commands Communication Parameter ChangesManual Scanning Interaction Keyboard Wedge Parameters Wedge Mode Enable @06656 User’s / Programming Guide Explained in Appendix a Symbologies Disable UPC both a and EUPC a and E Disable Expanded UPC-E *#@ Enable Expanded UPC-E User’s / Programming Guide Disable UPC-E Enable transmissionof UPC-E check digitEAN/JAN Disable EAN/JAN 8 or 13 Digit #@Disable EAN-8 independently Code Disable CodeDo Not Xmit Start and STOP*#@ Transmit Start and Stop Following are only valid if CHK Char is enabledDisable Interleaved Code 2 of 5*#@ Code 2 of 5 InterleavedMaximum Length I 2 of 5 specified by two digits Code 2 of 5 Standard Disable Codabar *#@ Enable Code 128 *#@Enable Codabar Minimum Length specified by two digitsMaximum Length specified by two digits Enable Transmission of START/ Stop CharacterMSI/Plessey Enable Code Standard Code 16K Enable 16K Code Disable 16K CodeDigit Selection Symbol Function Symbology Identifiers06656 Bology identifiers Programming SymbolEAN-13 Code Symbology IdentifiersStandard 2/5 Code MSI/PlesseySelect Code Type Wand Emulation ParametersBar Code Polarity Transmission RateInches per second# Data Synchronization Disable Data # Synchronization Enable Data SynchronizationActive # Polarity High Active Polarity Low Memory Module Disable Memory Module*# Enable Memory Module SetupMarker Beam Enable Marker Beam Disable Marker Beam06656 Service and Warranty Scanner LabelingHazardous visible light exposure Maintenance CleaningInspection PSC Website Support PSC Website TekForum Technical SupportReseller Technical Support Telephone Technical SupportHexadecimal Conversion Table Appendix aPart a Part B Ascii HEX Function Primary Function Key TablePC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25 Secondary Function Key TablesIBM 3171/3181/3191 and IBM VT220/320/420 Apple MacIntosh 06656 User’s / Programming Guide Declaration of Conformity PSC Inc