Datalogic Scanning DS2200 SH2348, DS1100 SH2347 manual Memory Module

Page 70

Memory Module

The Memory Module option is a factory installed feature that is requested at time of order. The Memory Module option allows the 5300 series scanner to store decoded labels in an internal battery backed up RAM. The stored buffered labels can then be transmitted some time later. The user may also choose an interlabel transmission delay in cases where the transmission rate of the buffered decoded label is faster than the receiving equipment.

Switching to the Memory Module mode is achieved by scanning the Enable Memory Module symbol. The Memory Module is cleared every time Memory Module is enabled. While in Memory Module mode, the scanner will store in its internal memory all scanned bar code labels.

The user can transmit the stored labels by scanning the Send Memory Module symbol. When the transmission rate is faster than the receiv- ing equipment, the user can program a delay that will occur after each label. The delay is programmed by scanning the Interlabel Delay symbol (see the Intercharacter Delay page of the Setup Parameters section), followed by two digits (see Digit Selection page) to set the delay duration. The allowable range of values is 00 to 99, where 99 corresponds to a delay of 9.9 seconds.

In order to restore the scanner to normal operation, the user needs to scan the Disable Memory Module label. Also the user may clear the contents of the Memory Module by scanning the Clear Memory Mod- ule symbol or by disabling and enabling Memory Module. Stored labels are cleared whenever Memory Module is enabled.

The stored data in the Memory Module cannot be trans-

mitted through the Wand Emulation output.

NOTE

The Memory Module feature is to be used only with the Memory Module mode. When used with scanners without this optional mode, programmed instructions will be

CAUTION damaged.

62

User’s / Programming Guide

Image 70
Contents User’s / Programming Guide PSC Inc DisclaimerPage Page Table of Contents Message Formatting Serial CommandsKeyboard Wedge Parameters Symbologies Wand Emulation ParametersScanner Labeling IiiMemory Module Technical SupportUser’s / Programming Guide Introduction Unpacking InstallationCable Installation Keyboard WedgeTerminal Power-Up Sequence Connecting the Power SupplyConnecting a Magnetic Stripe Reader Scanning Reset to Default ZA will cause the PSC scanSerial RS232 Mode Serial TTL ModeSerial Communications AutoSense Operation Enable AutoSense Disable AutoSense Scanner holder Stand baseSame Code Wand Emulation Enable Wedge Enable Serial ModeWand Emulation Operation Code Type = Same Code Wand EmulationWedge Mode Options Setup OverviewWand Emulation Options Baud Rate Protocol Parity Serial Communication and Wedge OptionsData Synchronization Stop BitsCode SymbologiesCode Interleaved 2 Standard 2 Codabar Vice representativeParameters Selection Guidelines Beeper On Volume LowExamples User’s / Programming Guide Baud Rate Reset DefaultSerial Communication Select Serial OutputBit Options Data Stop Bits Parity Data TransmissionOdd Even Mark Space Mark Space None Bit, No ParityCommunications Protocol Inverted Serial CommunicationsCTS Disable Stop/Go Protocol Enable Stop/Go Protocol No Read Option Enable No Read Disable No ReadLabel Buffering Full Buffering No Buffering One Label BufferingDisable External Trigger#*@ External Trigger+ Menu Commands Parameter MessagesEnable Parameter Messages Disable Parameter Messages External Trigger OperationGeneral Parameters Intercharacter DelayNo interlabel delay *@ Set interlabel delay 0-9.9 seconds External TriggerTransmission Mode System StatusEnable Continuous@ Full Power Enable Standby *# Power ConsumptionDisplay Configuration Laser RedundancyBeeper Off Beeper On Volume Low Laser TimeoutEnable 4 Times Laser Redundancy Beeper OperationPrefixes and Suffixes Beeper On Volume Medium Beeper On Volume Loud *#@Message Formatting Programmable options do not apply in Wand Emu LationSuffix PrefixPrefix = None*# Prefix = STX Prefix = SOH Suffix = CR and LF Terminal ID Select Suffix = ETB NULCode Identifier Code Identifier CharactersPostamble Preamble or Postamble SelectionPreamble 0,0 hexadecimalUser’s / Programming Guide Serial Commands General Serial Command FormatEnable I 2 of 5 with check digit Command FunctionBeeper Off CR-LF Ack Communication Parameter Changes Power Standby and Serial CommandsManual Scanning Interaction Wedge Mode Enable @ Keyboard Wedge Parameters06656 User’s / Programming Guide Explained in Appendix a Disable UPC both a and E SymbologiesUPC a and E Disable Expanded UPC-E *#@ Enable Expanded UPC-E User’s / Programming Guide Enable transmissionof UPC-E check digit Disable UPC-EDisable EAN/JAN 8 or 13 Digit #@ EAN/JANDisable EAN-8 independently Disable Code CodeFollowing are only valid if CHK Char is enabled Do Not Xmit Start and STOP*#@ Transmit Start and StopCode 2 of 5 Interleaved Disable Interleaved Code 2 of 5*#@Maximum Length I 2 of 5 specified by two digits Code 2 of 5 Standard Enable Codabar Enable Code 128 *#@Disable Codabar *#@ Minimum Length specified by two digitsEnable Transmission of START/ Stop Character Maximum Length specified by two digitsMSI/Plessey Enable Code Standard Code Enable 16K Code Disable 16K Code 16KDigit Selection Symbology Identifiers Symbol Function06656 Programming Symbol Bology identifiersStandard 2/5 Code Symbology IdentifiersEAN-13 Code MSI/PlesseyBar Code Polarity Wand Emulation ParametersSelect Code Type Transmission RateInches per second# Disable Data # Synchronization Enable Data Synchronization Data SynchronizationActive # Polarity High Active Polarity Low Memory Module Setup Disable Memory Module*# Enable Memory ModuleEnable Marker Beam Disable Marker Beam Marker Beam06656 Scanner Labeling Service and WarrantyHazardous visible light exposure Cleaning MaintenanceInspection Reseller Technical Support Technical SupportPSC Website Support PSC Website TekForum Telephone Technical SupportAppendix a Hexadecimal Conversion TablePart a Part B Primary Function Key Table Ascii HEX FunctionSecondary Function Key Tables PC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25IBM 3171/3181/3191 and IBM VT220/320/420 Apple MacIntosh 06656 User’s / Programming Guide Declaration of Conformity PSC Inc