Datalogic Scanning DS2200 SH2348, DS1100 SH2347 manual Beeper Off CR-LF Ack, Command Function

Page 40

Beeper Off CR-LF Ack

If the scanner receives an unknown or improperly formatted code, or if the required parameters are missing or out-of-range, it sends a NAK (15H) Code.

Command

Function

 

 

STX ESC PC ETX

Enable I 2 of 5 with check digit

 

 

STX ESC PD12 ETX

Set I 2 of 5 minimum length to 12

 

 

STX ESC PE14 ETX

Set I 2 of 5 maximum length to 12

 

 

STX ESC KB31323334 ETX

Set Preamble to ‘1234’

 

 

STX ESC LB61626364

Set Postamble to ‘abcd’

 

 

Serial Commands to Use with Caution

Some of the commands in this manual should not be used as serial commands because of the consequences they produce. All PSC scan- ners use the same hardware components to implement both serial communication and wand emulation. This means that all serial com- munication functions are disabled during wand emulation, and vice versa. Because of this, issuing any of the commands in Table 5 causes the scanner to enter its Wand Emulation mode, thereby disabling serial communication.

CB

CC

Wand Emulation, Code 39 Output

Wand Emulation, Same Code Output

Furthermore, because the scanner acts upon a command and then sends ACK or NAK, neither or these codes will be transmitted in response to any of the above commands. In Table 5 only the com- mand letters are listed; the complete command is prefixed with STX ESC, and suffixed with ETX. Because it is not possible to set (via serial command) two Wand Emulation parameters (emulation speed and polarity, for example), scanners to be used in Wand Emulation envi- ronments must be programmed by scanning labels from this manual.

32

User’s / Programming Guide

Image 40
Contents User’s / Programming Guide PSC Inc DisclaimerPage Page Table of Contents Serial Commands Keyboard Wedge Parameters SymbologiesMessage Formatting Wand Emulation ParametersIii Memory ModuleScanner Labeling Technical SupportUser’s / Programming Guide Introduction Installation Cable InstallationUnpacking Keyboard WedgeConnecting the Power Supply Connecting a Magnetic Stripe ReaderTerminal Power-Up Sequence Scanning Reset to Default ZA will cause the PSC scanSerial RS232 Mode Serial TTL ModeSerial Communications AutoSense Operation Enable AutoSense Disable AutoSense Scanner holder Stand baseEnable Wedge Enable Serial Mode Wand Emulation OperationSame Code Wand Emulation Code Type = Same Code Wand EmulationWedge Mode Options Setup OverviewWand Emulation Options Serial Communication and Wedge Options Data SynchronizationBaud Rate Protocol Parity Stop BitsSymbologies Code Interleaved 2 Standard 2 CodabarCode Vice representativeParameters Selection Guidelines Beeper On Volume LowExamples User’s / Programming Guide Reset Default Serial CommunicationBaud Rate Select Serial OutputBit Options Data Stop Bits Parity Data TransmissionOdd Even Mark Space Mark Space Bit, No Parity Communications ProtocolNone Inverted Serial CommunicationsCTS Disable Stop/Go Protocol Enable Stop/Go Protocol Enable No Read Disable No Read Label BufferingNo Read Option Full Buffering No Buffering One Label BufferingMenu Commands Parameter Messages Enable Parameter Messages Disable Parameter MessagesDisable External Trigger#*@ External Trigger+ External Trigger OperationIntercharacter Delay No interlabel delay *@ Set interlabel delay 0-9.9 secondsGeneral Parameters External TriggerTransmission Mode System StatusPower Consumption Display ConfigurationEnable Continuous@ Full Power Enable Standby *# Laser RedundancyLaser Timeout Enable 4 Times Laser RedundancyBeeper Off Beeper On Volume Low Beeper OperationBeeper On Volume Medium Beeper On Volume Loud *#@ Message FormattingPrefixes and Suffixes Programmable options do not apply in Wand Emu LationSuffix PrefixPrefix = None*# Prefix = STX Prefix = SOH Suffix = CR and LF Terminal ID Select Suffix = ETB NULCode Identifier Code Identifier CharactersPreamble or Postamble Selection PreamblePostamble 0,0 hexadecimalUser’s / Programming Guide Serial Commands General Serial Command FormatEnable I 2 of 5 with check digit Command FunctionBeeper Off CR-LF Ack Communication Parameter Changes Power Standby and Serial CommandsManual Scanning Interaction Wedge Mode Enable @ Keyboard Wedge Parameters06656 User’s / Programming Guide Explained in Appendix a Disable UPC both a and E SymbologiesUPC a and E Disable Expanded UPC-E *#@ Enable Expanded UPC-E User’s / Programming Guide Enable transmissionof UPC-E check digit Disable UPC-EDisable EAN/JAN 8 or 13 Digit #@ EAN/JANDisable EAN-8 independently Disable Code CodeFollowing are only valid if CHK Char is enabled Do Not Xmit Start and STOP*#@ Transmit Start and StopCode 2 of 5 Interleaved Disable Interleaved Code 2 of 5*#@Maximum Length I 2 of 5 specified by two digits Code 2 of 5 Standard Enable Code 128 *#@ Disable Codabar *#@Enable Codabar Minimum Length specified by two digitsEnable Transmission of START/ Stop Character Maximum Length specified by two digitsMSI/Plessey Enable Code Standard Code Enable 16K Code Disable 16K Code 16KDigit Selection Symbology Identifiers Symbol Function06656 Programming Symbol Bology identifiersSymbology Identifiers EAN-13 CodeStandard 2/5 Code MSI/PlesseyWand Emulation Parameters Select Code TypeBar Code Polarity Transmission RateInches per second# Disable Data # Synchronization Enable Data Synchronization Data SynchronizationActive # Polarity High Active Polarity Low Memory Module Setup Disable Memory Module*# Enable Memory ModuleEnable Marker Beam Disable Marker Beam Marker Beam06656 Scanner Labeling Service and WarrantyHazardous visible light exposure Cleaning MaintenanceInspection Technical Support PSC Website Support PSC Website TekForumReseller Technical Support Telephone Technical SupportAppendix a Hexadecimal Conversion TablePart a Part B Primary Function Key Table Ascii HEX FunctionSecondary Function Key Tables PC/AT, PC/XT, IBM 3151, and IBM PS/2 Model 57/25IBM 3171/3181/3191 and IBM VT220/320/420 Apple MacIntosh 06656 User’s / Programming Guide Declaration of Conformity PSC Inc