Technical

Technical information

Choosing a position

Your DF450 should be kept clear of dust, moisture, high temperature and vibration and should not be exposed to direct sunlight. Don’t install it close to radiators or air-conditioning outlets or in excessively warm, humid or dusty places.

Warning

The apparatus is only designed to be operated in a normal office or domestic environment where the relative humidity does not exceed 60%. It should not be used in bathrooms or near water.

Connecting to the UK network

DF450 is tested and approved for connection to the UK network, provided that it is used in accordance with the guidelines in this booklet.

Approval number

BABT Certificate Number/Approval Number for the DF450 503727 APPROVED for connection to telecommunication systems specified in the instructions for use subject to conditions set out in them. CE compliant to 89/336/CEE (EMC Directive)

Approval for use

This apparatus has been approved for use with the following facilities:

Storage of telephone numbers for retrieval by a predetermined code. (If problems occur, verify stored number).

Automatic call initiation.

Use on a PBX which returns secondary proceed indication. Operation in the presence or absence of initial or secondary proceed indication.

Automatic dialling facilities.

Automatic storage of last number dialled. Automatic repeat attempt facilities.

Auto clear from the originating end. Series connection facility.

Call progress monitor.

You may connect it:

to direct exchange lines:

to extensions with new plug and socket arrangements provided with these direct exchange lines;

to compatible switchboards.

You may NOT connect it:

• to shared service (party) lines.

The connection to the telecommunication system must be unplugged before the earth is disconnected. The connection to the telecommunication system must not be hardwired.

This apparatus may be used on telecommunications systems employing loop disconnect or MF signalling.

Any other usage will invalidate the approval of the apparatus if, as a result, it then ceases to conform to the standards against which approval was granted.

How many phones you can have

Your exchange line provides only a small current to make your telephone ring. Although you may have any number of sockets it is important to limit the number of telephones and other items of apparatus connected to the line by these sockets. This ensures that each telephone will receive enough current to ring.

Every telephone or item of apparatus has a Ringer Equivalence Number (REN)

In most cases a standard line should provide enough current for two or more telephones or items of apparatus, if the RENs add up to no more than 4.

DF450 has a REN of 3. Any telephone provided by BT may be assumed to have a REN of 1 unless otherwise stated on the base. Even where the number of telephones has been limited, there is no guarantee that the different types of telephone on the same line will ring.

47

Image 50
Contents DF450 plain paper fax machine User guideTop view Automatic documentTop view with the printer cover and control panel open Control panel Last TXThis guide For your records Setting upFollow these steps to get your DF450 ready Plug into the BT socket Plug the mains lead into a convenient socket Fit your DF450 attachments to the main unitTo fit the sent document tray Fully assembled DF450 with attachments fitted Install the print cartridge Place paper in the automatic sheet feederClose cover Connecting a phone or an answering machine to your DF450 Setting the time and dateSetting your name and fax number Name and fax number position International codesUsing your DF450 Normal dialling Fax is received and printed Setting the answer mode Which mode is correct for you?Using a phone or answering machine with your DF450 EitherRemote control from an extension Polling Insert the documentStoring one-touch and Quickdial numbers and names Press the Function button the display shows FAX SET-UP To store Quickdial numbers and names Press the Function button, display shows FAX SET-UP To change the speaker volume Fax monitorPrint-outs To automatically print individual reportsTo print a list of stored names, numbers and settings Adjusting for different-size paper Changing the size of incoming faxes Adjusting the beep in phone/fax mode Adjusting the silence lapse timeInserting a pause Connecting your DF450 to a direct exchange lineConnecting your DF450 to a private switchboard Setting the external button Error correction mode ECMDiagnostics SpeedMaintenance Blank sheet of paper. If the copy is not clear DF450 doesn’t print properly If printing paper is jammed Freefone 0800 Industry standard test sheet Display messages Automatic test procedure No action Operation Transmission report messages Journal report messages Message in Result Interpretation Action Field Engaged tone detected before Repeat transmission Technical Specifications and General Characteristics Electrical characteristicsTechnical information Voltage drop Index REN Index Page Offices in Europe, North America, Japan and Asia Pacific