Dell E08J Series owner manual RAID Controller Modules

Page 15

2

Controller Modules

RAID Controller Modules

RAID controller modules provide high-performance, advanced virtual disk configuration, and fault- tolerant disk subsystem management. Each RAID controller module contains 4 GB of mirrored cache for high availability and is protected by a battery powered cache offload mechanism.

NOTE: 8 GB mirrored cache is an optional feature.

RAID controller modules provide the following data path and enclosure management functions:

Monitoring and controlling enclosure environment elements (temperature, fans, power supplies, and enclosure LEDs)

Controlling access to the physical disks

Communicating enclosure attributes and states to the host server and management station

MD3860f Fibre Channel RAID Controller Module Features And Indicators

Figure 8. MD3860f Fibre Channel RAID Controller Module Features and Indicators

Item

Indicator, Button, or

Icon

Description

 

Connector

 

 

 

 

 

 

1

Ethernet management

 

Provides a 100/1000 Mbps Ethernet connection for out-

 

port

 

of-band management of the enclosure.

2

Reserved Ethernet port

 

Reserved port.

15

Image 15
Contents Dell PowerVault MD3860f Storage Arrays Page Contents Troubleshooting your system Technical Specifications Getting help Dell PowerVault Modular Disk Storage Manager IntroductionRelated Documentation Front-Panel Features Front-Panel FeaturesFront-Bezel Indicators Front-Panel IndicatorsBlue Back-Panel Features Back-Panel FeaturesCooling Fan Module Indicators Cooling Fan Module LED Indicator CodesPower Supply Module Features and Status Indicators Power Supply Module Features And IndicatorsPhysical-Disk LED Indicators Physical-Disk LED IndicatorsFrom the system RAID Controller Modules Controller ModulesHost Channel LED Link Rate Indications Fibre Optic Cable Connection SFP+ Transceivers Fibre Optic And SAS CablesExpansion Controller Modules MD3060e Expansion Module Features And IndicatorsRAID Controller Module-Additional Features Battery Backup UnitStorage Array Thermal Shutdown System Password Reset Removing And Installing The Front Bezel Installing The Front BezelRecommended Tools Service Action Allowed Indicator LED Physical-Disk DrawersRemoving The Front Bezel Inside the Physical-Disk Drawer Opening The Physical-Disk DrawerRemoving The Physical-Disk Drawer Closing The Physical-Disk DrawerPage Removing and Installing the Physical-Disk Drawer Installing The Physical-Disk DrawerPhysical Disk Installation Guidelines Physical DisksRemoving a Physical Disk From a Physical-Disk Carrier Inch physical drive cage Guide pin Release handle Installing a Physical Disk In a Physical-Disk Carrier Removing a Physical Disk From a Physical-Disk Drawer SAS Chain Cables Installing a Physical Disk In a Physical-Disk DrawerRemoving The SAS Chain Cables Removing and Installing the SAS Chain Cables Installing The SAS Chain CablesRemoving a RAID Controller Module Or Expansion Module Installing a RAID Controller Module Or Expansion Module Closing The RAID Controller Module Opening The RAID Controller ModuleReplacing the SFP+ Transceiver Replacing The SFP+ TransceiverRemoving The RAID Controller Module Backup Battery Unit RAID Controller Module Backup Battery UnitPower Supplies Installing The RAID Controller Module Backup Battery UnitRemoving a Power Supply Module Removing and Installing the power supply module Installing a Power Supply ModuleRemoving a Cooling Fan Module Cooling Fan ModulesRemoving and Installing the Cooling Fan Module Installing a Cooling Fan ModuleTroubleshooting An SFP+ Transceiver Troubleshooting Loss Of CommunicationRemoving an SFP+ Module Troubleshooting Power Supply Modules Troubleshooting External ConnectionsTroubleshooting Expansion Enclosure Management Modules Troubleshooting Array Cooling ProblemsIf Both LEDs For Any Given FC in Port Are Unlit Troubleshooting RAID Controller ModulesTroubleshooting Physical Disks If The Link Status LEDs Are Not GreenTroubleshooting a Wet Storage Array Troubleshooting Array And Expansion Enclosure ConnectionsNoncritical Conditions Troubleshooting a Damaged ArrayController Failure Conditions Critical ConditionsECC Errors PCI ErrorsInvalid Storage Array Technical Specifications Page Tested Page Locating your system service tag Contacting DellDocumentation feedback