Serial connector (debug port)
Management Ethernet connector
FC connectors
NOTE: SAS and FC connections to the same host is not supported.
Two SAS OUT ports, it is recommended that you use the first port for expansion to an additional PowerVault MD3060e expansion enclosure. Only one expansion port is supported at any given time.
NOTE: SAS connectors are
One mini USB port
NOTE: For technical support use only.
One 100/1000 Mbps Ethernet connection for out-
Four FC IN ports to connect hosts
NOTE: Directly attaching to the FC ports is not supported. The host connection must use a FC switch.
Power
AC power supply (per power supply)
Wattage | 1755 W |
Heat dissipation (maximum) | 5988 BTU/hr |
NOTE: Heat dissipation is calculated using the power supply wattage rating. The heat dissipation values are for the entire system which includes chassis and two controllers.
Voltage | 220 V AC, autoranging, 50 Hz/60 Hz |
NOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.
Battery | 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery |