Dell E08J Series owner manual Invalid Storage Array, ECC Errors, PCI Errors

Page 50

One RAID controller module in a redundant configuration has failed

A battery has failed or has been removed

A physical disk in a redundant virtual disk has failed

Invalid Storage Array

The RAID controller module is supported only in a Dell-supported storage array. After installation in the storage array, the controller performs a set of validation checks. The array status LED is lit with a steady amber color while the RAID controller module completes these initial tests and the controllers are booted successfully. If the RAID controller module detects a non-Dell supported storage array, the controller does not startup. The RAID controller module does not generate any events to alert you in the event of an invalid array, but the array status LED is lit with a flashing amber color to indicate a fault state.

ECC Errors

RAID controller firmware can detect ECC errors and can recover from a single-bit ECC error whether the RAID controller module is in a redundant or nonredundant configuration. A storage array with redundant controllers can recover from multi-bit ECC errors as well because the peer RAID controller module can take over, if necessary.

The RAID controller module fails over if it experiences up to 10 single-bit errors, or up to three multi-bit errors.

PCI Errors

The storage array firmware can detect and only recover from PCI errors when the RAID controller modules are configured for redundancy. If a virtual disk uses cache mirroring, it fails over to its peer RAID controller module, which initiates a flush of the dirty cache.

50

Image 50
Contents Dell PowerVault MD3860f Storage Arrays Page Contents Troubleshooting your system Technical Specifications Getting help Related Documentation Dell PowerVault Modular Disk Storage ManagerIntroduction Front-Panel Features Front-Panel FeaturesFront-Panel Indicators Front-Bezel IndicatorsBlue Back-Panel Features Back-Panel FeaturesCooling Fan Module LED Indicator Codes Cooling Fan Module IndicatorsPower Supply Module Features And Indicators Power Supply Module Features and Status IndicatorsPhysical-Disk LED Indicators Physical-Disk LED IndicatorsFrom the system Controller Modules RAID Controller ModulesHost Channel LED Link Rate Indications SFP+ Transceivers Fibre Optic And SAS Cables Fibre Optic Cable ConnectionMD3060e Expansion Module Features And Indicators Expansion Controller ModulesStorage Array Thermal Shutdown RAID Controller Module-Additional FeaturesBattery Backup Unit System Password Reset Recommended Tools Removing And Installing The Front BezelInstalling The Front Bezel Removing The Front Bezel Service Action Allowed Indicator LEDPhysical-Disk Drawers Opening The Physical-Disk Drawer Inside the Physical-Disk DrawerClosing The Physical-Disk Drawer Removing The Physical-Disk DrawerPage Installing The Physical-Disk Drawer Removing and Installing the Physical-Disk DrawerRemoving a Physical Disk From a Physical-Disk Carrier Physical Disk Installation GuidelinesPhysical Disks Inch physical drive cage Guide pin Release handle Installing a Physical Disk In a Physical-Disk Carrier Removing a Physical Disk From a Physical-Disk Drawer Installing a Physical Disk In a Physical-Disk Drawer SAS Chain CablesRemoving The SAS Chain Cables Installing The SAS Chain Cables Removing and Installing the SAS Chain CablesRemoving a RAID Controller Module Or Expansion Module Installing a RAID Controller Module Or Expansion Module Opening The RAID Controller Module Closing The RAID Controller ModuleReplacing The SFP+ Transceiver Replacing the SFP+ TransceiverRAID Controller Module Backup Battery Unit Removing The RAID Controller Module Backup Battery UnitRemoving a Power Supply Module Power SuppliesInstalling The RAID Controller Module Backup Battery Unit Installing a Power Supply Module Removing and Installing the power supply moduleCooling Fan Modules Removing a Cooling Fan ModuleInstalling a Cooling Fan Module Removing and Installing the Cooling Fan ModuleTroubleshooting Loss Of Communication Troubleshooting An SFP+ TransceiverRemoving an SFP+ Module Troubleshooting External Connections Troubleshooting Power Supply ModulesTroubleshooting Array Cooling Problems Troubleshooting Expansion Enclosure Management ModulesIf The Link Status LEDs Are Not Green Troubleshooting RAID Controller ModulesTroubleshooting Physical Disks If Both LEDs For Any Given FC in Port Are UnlitTroubleshooting Array And Expansion Enclosure Connections Troubleshooting a Wet Storage ArrayCritical Conditions Troubleshooting a Damaged ArrayController Failure Conditions Noncritical ConditionsInvalid Storage Array ECC ErrorsPCI Errors Technical Specifications Page Tested Page Documentation feedback Locating your system service tagContacting Dell