Dell E08J Series SAS Chain Cables, Installing a Physical Disk In a Physical-Disk Drawer

Page 31

7.release tab (12)

Installing A Physical Disk In A Physical-Disk Drawer

CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

1.Rotate the physical-disk carrier handle upward to the vertical position.

2.Align the two raised buttons with the notches on the physical-disk drawer, lower the physical disk into the slot in the physical-disk drawer.

NOTE: Ensure that you install the physical disk from left to right and from front to back.

3.Rotate the handle downward until the physical disk is properly seated in the connector and the physical-disk carrier handle snaps into place.

4.Close the physical-disk drawer.

5.Install the front bezel.

SAS Chain Cables

There are two SAS cable chains on each side of the physical-disk drawer that connects the physical disks installed in the physical-disk drawer to the midplane.

The connector on each SAS chain cable that connects to the physical-disk drawer is oriented horizontally.

The connector on each SAS chain cable that connects to the midplane is oriented vertically.

Figure 20. SAS Chain Cable Features

1.SAS cable connector on the physical-disk drawer (oriented horizontally)

2.SAS cable connector to the midplane (oriented vertically)

31

Image 31
Contents Dell PowerVault MD3860f Storage Arrays Page Contents Troubleshooting your system Technical Specifications Getting help Introduction Dell PowerVault Modular Disk Storage ManagerRelated Documentation Front-Panel Features Front-Panel FeaturesFront-Bezel Indicators Front-Panel IndicatorsBlue Back-Panel Features Back-Panel FeaturesCooling Fan Module Indicators Cooling Fan Module LED Indicator CodesPower Supply Module Features and Status Indicators Power Supply Module Features And IndicatorsPhysical-Disk LED Indicators Physical-Disk LED IndicatorsFrom the system RAID Controller Modules Controller ModulesHost Channel LED Link Rate Indications Fibre Optic Cable Connection SFP+ Transceivers Fibre Optic And SAS CablesExpansion Controller Modules MD3060e Expansion Module Features And IndicatorsBattery Backup Unit RAID Controller Module-Additional FeaturesStorage Array Thermal Shutdown System Password Reset Installing The Front Bezel Removing And Installing The Front BezelRecommended Tools Physical-Disk Drawers Service Action Allowed Indicator LEDRemoving The Front Bezel Inside the Physical-Disk Drawer Opening The Physical-Disk DrawerRemoving The Physical-Disk Drawer Closing The Physical-Disk DrawerPage Removing and Installing the Physical-Disk Drawer Installing The Physical-Disk DrawerPhysical Disks Physical Disk Installation GuidelinesRemoving a Physical Disk From a Physical-Disk Carrier Inch physical drive cage Guide pin Release handle Installing a Physical Disk In a Physical-Disk Carrier Removing a Physical Disk From a Physical-Disk Drawer SAS Chain Cables Installing a Physical Disk In a Physical-Disk DrawerRemoving The SAS Chain Cables Removing and Installing the SAS Chain Cables Installing The SAS Chain CablesRemoving a RAID Controller Module Or Expansion Module Installing a RAID Controller Module Or Expansion Module Closing The RAID Controller Module Opening The RAID Controller ModuleReplacing the SFP+ Transceiver Replacing The SFP+ TransceiverRemoving The RAID Controller Module Backup Battery Unit RAID Controller Module Backup Battery UnitInstalling The RAID Controller Module Backup Battery Unit Power SuppliesRemoving a Power Supply Module Removing and Installing the power supply module Installing a Power Supply ModuleRemoving a Cooling Fan Module Cooling Fan ModulesRemoving and Installing the Cooling Fan Module Installing a Cooling Fan ModuleTroubleshooting An SFP+ Transceiver Troubleshooting Loss Of CommunicationRemoving an SFP+ Module Troubleshooting Power Supply Modules Troubleshooting External ConnectionsTroubleshooting Expansion Enclosure Management Modules Troubleshooting Array Cooling ProblemsIf Both LEDs For Any Given FC in Port Are Unlit Troubleshooting RAID Controller ModulesTroubleshooting Physical Disks If The Link Status LEDs Are Not GreenTroubleshooting a Wet Storage Array Troubleshooting Array And Expansion Enclosure ConnectionsNoncritical Conditions Troubleshooting a Damaged ArrayController Failure Conditions Critical ConditionsPCI Errors ECC ErrorsInvalid Storage Array Technical Specifications Page Tested Page Contacting Dell Locating your system service tagDocumentation feedback