Item | Indicator, Button, or | Icon | Description |
| Connector |
|
|
|
|
|
|
3 | 12 Gbps SAS IN port (2) |
| Provides |
4 | USB port |
| Reserved port. |
5 | Mini USB port |
| Dell support only. |
6 | Password reset switch |
| Pressing this switch resets the password. |
7 | SAS expansion port (2) |
| Provides SAS OUT connection for cabling to a daisy |
|
|
| chained expansion enclosure. Port 0 expansion port is |
|
|
| recommended. |
8 | 16 Gbps FC IN port (4) |
| Provides |
9 | Seven segment display |
| Displays status or error codes for the storage array. |
| sequence |
|
|
10 | System identification |
| The system identification indicator blinks blue when |
| indicator |
| system identification switch |
|
|
| enclosure front panel is pressed. |
11 | Controller fault |
| The controller fault indicator lights amber when controller |
| indicator |
| fault is detected. |
12 | Controller power |
| The controller power indicator lights green when |
| indicator |
| controller power is on. |
13 | Cache active or cache |
| The cache active or cache offload indicator lights green |
| offload indicator |
| when |
|
|
| If AC power fails, this LED changes to indicate cache |
|
|
| offload status. |
|
|
| If the password reset function has successfully changed |
|
|
| the password, this LED flashes on and off briefly. |
14 | Battery fault indicator |
| The battery fault indicator lights amber when battery |
|
|
| backup unit or battery has failed. |
Host Channel LED Link Rate Indications
Above each FC port is a pair of LED indicators. The status of any FC port can be determined by applying the condition of each LED pair.
Table 1. LED Status Indicators
LED 0 | LED 1 | Port Status |
|
|
|
Off | Off | Link down |
On | Off | 4 Gbps link |
Off | On | 8 Gbps link |
On | On | 16 Gbps link |
16