Cisco Systems UCSCPCIECSC02 manual Enable PXE Boot check box, Enable Uplink Failover check box

Page 22

Managing Network Adapters

Viewing vNIC Properties

Name

Description

Default VLAN field

If there is no default VLAN for this vNIC, click NONE. Otherwise,

 

click the second radio button and enter a VLAN ID between 1 and 4094

 

in the field.

 

Note

This option cannot be used in NIV

 

 

mode.

VLAN Mode drop-down list

If you want to use VLAN trunking, select TRUNK. Otherwise, select

 

ACCESS.

 

Note

This option cannot be used in NIV

 

 

mode.

Rate Limit field

If you want this vNIC to have an unlimited data rate, select OFF.

 

Otherwise, click the second radio button and enter a rate limit in the

 

associated field.

 

Enter an integer between 1 and 10,000 Mbps.

 

Note

This option cannot be used in NIV

 

 

mode.

Enable PXE Boot check box

Check this box if the vNIC can be used to perform a PXE boot.

Channel Number field

Select the channel number that will be assigned to this vNIC.

 

Note

NIV mode is required for this

 

 

option.

Port Profile drop-down list

Select the port profile that should be associated with the vNIC.

 

This field displays the port profiles defined on the switch to which this

 

server is connected.

 

Note

NIV mode is required for this

 

 

option.

Enable Uplink Failover check box

Check this box if traffic on this vNIC should fail over to the secondary

 

interface if there are communication problems.

 

Note

NIV mode is required for this

 

 

option.

Failback Timeout field

After a vNIC has started using its secondary interface, this setting

 

controls how long the primary interface must be available before the

 

system resumes using the primary interface for the vNIC.

 

Enter a number of seconds between 0 and 600.

 

Note

NIV mode is required for this

 

 

option.

Step 9 In the Ethernet Interrupt area, review the information in the following fields:

 

Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.4

22

OL-23489-08

Image 22 Contents
Managing Network Adapters Overview of the Cisco UCS C-Series Network AdaptersViewing Network Adapter Properties Cisco UCS P81E Virtual Interface CardProduct Name column Cimc Management EnabledPCI Slot column Serial Number columnNIV Mode field Configuration Pending fieldFIP Mode field FaultConfiguring Adapter Properties Enable NIV Mode check box Number of VM FEX Interfaces Enable FIP Mode check boxClick Save Changes Viewing vHBA Properties Managing vHBAsGuidelines for Managing vHBAs Name fieldDefault Vlan field FC SAN Boot check boxEnable Persistent LUN Binding Class of Service drop-down listPort Down Timeout field Enable FCP Error RecoveryLink Down Timeout field Ratov fieldThrottle Count field Interrupt Mode drop-down listFlogi Timeout field LUNs per Target fieldModifying vHBA Properties World Wide Node Name field Error Recovery area, update the following fields Fibre Channel Interrupt area, update the following fields Name Creating a vHBA Click Add vHBADeleting a vHBA VHBA Boot TableCreating a Boot Table Entry Fc1 Deleting a Boot Table Entry VHBA Persistent BindingViewing Persistent Bindings Rebuilding Persistent Bindings Managing vNICsGuidelines for Managing vNICs Trust Host CoS check box Viewing vNIC PropertiesPCI Order field Enable Uplink Failover check box Enable PXE Boot check boxFailback Timeout field Coalescing Type drop-down list Interrupt Count fieldCoalescing Time field Receive Queue Count fieldEnable Large Receive check box Enable TCP Rx OffloadEnable TCP Tx Offload Transmit Queue Ring Size fieldEnable TCP-IPv6 Extension RSS Modifying vNIC PropertiesAccess Ethernet Interrupt area, update the following fields Ethernet Transmit Queue area, update the following fields Enable TCP Receive Side Scaling Creating a vNIC Click Add vNICVirtual Machine Fabric Extender Managing VM FEXDeleting a vNIC Viewing Virtual FEX PropertiesProperties button Vlan Mode columnPXE Boot field Uplink Failover columnInterrupt Mode field Coalescing Type fieldEnable IPv4 RSS field Enable TCP SegmentationEnable Large Receive field Enable TCP-IPv4 RSS fieldClick Export Configuration Backing Up and Restoring the Adapter ConfigurationExporting the Adapter Configuration Tftp Server IP Address fieldRestoring Adapter Defaults Importing the Adapter ConfigurationClick Import Configuration Managing Adapter Firmware Installing Adapter Firmware From a Local FileAdapter Firmware Installing Adapter Firmware From a Tftp Server Install Firmware buttonResetting the Adapter Activating Adapter FirmwareOL-23489-08
Related manuals
Manual 204 pages 40.67 Kb