Managing Network Adapters

Modifying vHBA Properties

Name

Description

Rate Limit field

The data rate limit for traffic on this vHBA, in Mbps.

 

If you want this vHBA to have an unlimited data rate, select OFF.

 

Otherwise, click the second radio button and enter an integer between

 

1 and 10,000.

 

Note

This option cannot be used in NIV

 

 

mode.

PCIe Device Order field

The order in which this vHBA will be used.

 

To let the system set the order, select ANY. To specify an order, select

 

the second radio button and enter an integer between 0 and 17.

EDTOV field

The error detect timeout value (EDTOV), which is the number of

 

milliseconds to wait before the system assumes that an error has

 

occurred.

 

Enter an integer between 1,000 and 100,000. The default is 2,000

 

milliseconds.

RATOV field

The resource allocation timeout value (RATOV), which is the number

 

of milliseconds to wait before the system assumes that a resource cannot

 

be properly allocated.

 

Enter an integer between 5,000 and 100,000. The default is 10,000

 

milliseconds.

Max Data Field Size field

The maximum size of the Fibre Channel frame payload bytes that the

 

vHBA supports.

 

Enter an integer between 256 and 2112.

Channel Number field

The channel number that will be assigned to this vHBA.

 

Enter an integer between 1 and 1,000.

 

Note

NIV mode is required for this

 

 

option.

Port Profile drop-down list

The port profile that should be associated with the vHBA, if any.

 

This field displays the port profiles defined on the switch to which this

 

server is connected.

 

Note

NIV mode is required for this

 

 

option.

Step 9 In the Error Recovery area, update the following fields:

Name

Description

Enable FCP Error Recovery

If checked, the system uses FCP Sequence Level Error Recovery

check box

protocol (FC-TAPE).

Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.4

OL-23489-08

13

Image 13
Contents Overview of the Cisco UCS C-Series Network Adapters Managing Network AdaptersCisco UCS P81E Virtual Interface Card Viewing Network Adapter PropertiesPCI Slot column Cimc Management EnabledProduct Name column Serial Number columnFIP Mode field Configuration Pending fieldNIV Mode field FaultConfiguring Adapter Properties Enable NIV Mode check box Number of VM FEX Interfaces Enable FIP Mode check boxClick Save Changes Guidelines for Managing vHBAs Managing vHBAsViewing vHBA Properties Name fieldEnable Persistent LUN Binding FC SAN Boot check boxDefault Vlan field Class of Service drop-down listLink Down Timeout field Enable FCP Error RecoveryPort Down Timeout field Ratov fieldFlogi Timeout field Interrupt Mode drop-down listThrottle Count field LUNs per Target fieldModifying vHBA Properties World Wide Node Name field Error Recovery area, update the following fields Fibre Channel Interrupt area, update the following fields Name Click Add vHBA Creating a vHBACreating a Boot Table Entry VHBA Boot TableDeleting a vHBA Fc1VHBA Persistent Binding Deleting a Boot Table EntryViewing Persistent Bindings Rebuilding Persistent Bindings Managing vNICsGuidelines for Managing vNICs Trust Host CoS check box Viewing vNIC PropertiesPCI Order field Enable Uplink Failover check box Enable PXE Boot check boxFailback Timeout field Coalescing Time field Interrupt Count fieldCoalescing Type drop-down list Receive Queue Count fieldEnable TCP Tx Offload Enable TCP Rx OffloadEnable Large Receive check box Transmit Queue Ring Size fieldModifying vNIC Properties Enable TCP-IPv6 Extension RSSAccess Ethernet Interrupt area, update the following fields Ethernet Transmit Queue area, update the following fields Enable TCP Receive Side Scaling Click Add vNIC Creating a vNICDeleting a vNIC Managing VM FEXVirtual Machine Fabric Extender Viewing Virtual FEX PropertiesPXE Boot field Vlan Mode columnProperties button Uplink Failover columnCoalescing Type field Interrupt Mode fieldEnable Large Receive field Enable TCP SegmentationEnable IPv4 RSS field Enable TCP-IPv4 RSS fieldExporting the Adapter Configuration Backing Up and Restoring the Adapter ConfigurationClick Export Configuration Tftp Server IP Address fieldRestoring Adapter Defaults Importing the Adapter ConfigurationClick Import Configuration Managing Adapter Firmware Installing Adapter Firmware From a Local FileAdapter Firmware Install Firmware button Installing Adapter Firmware From a Tftp ServerActivating Adapter Firmware Resetting the AdapterOL-23489-08