Managing Network Adapters

Modifying vNIC Properties

Name

Description

Name field

The name for the virtual NIC.

This name cannot be changed after the vNIC has been created.

MTU field

The maximum transmission unit, or packet size, that this vNIC accepts.

 

Enter an integer between 1500 and 9000.

Uplink Port drop-down list

The uplink port associated with this vNIC. All traffic for this vNIC goes

 

through this uplink port.

MAC Address field

The MAC address associated with the vNIC.

 

To let the adapter select an available MAC address from its internal

 

pool, select Auto. To specify an address, click the second radio button

 

and enter the MAC address in the corresponding field.

Class of Service drop-down list

The class of service to associate with traffic from this vNIC.

 

Select an integer between 0 and 6, with 0 being lowest priority and 6

 

being the highest priority.

 

Note

This option cannot be used in NIV

 

 

mode.

Trust Host CoS check box

Check this box if you want the vNIC to use the class of service provided

 

by the host operating system.

PCI Order field

The order in which this vNIC will be used.

 

To let the system set the order, select Any. To specify an order, select

 

the second radio button and enter an integer between 0 and 17.

Default VLAN field

If there is no default VLAN for this vNIC, click NONE. Otherwise,

 

click the second radio button and enter a VLAN ID between 1 and 4094

 

in the field.

 

Note

This option cannot be used in NIV

 

 

mode.

VLAN Mode drop-down list

If you want to use VLAN trunking, select TRUNK. Otherwise, select

 

ACCESS.

 

Note

This option cannot be used in NIV

 

 

mode.

Rate Limit field

If you want this vNIC to have an unlimited data rate, select OFF.

 

Otherwise, click the second radio button and enter a rate limit in the

 

associated field.

 

Enter an integer between 1 and 10,000 Mbps.

 

Note

This option cannot be used in NIV

 

 

mode.

Enable PXE Boot check box

Check this box if the vNIC can be used to perform a PXE boot.

 

Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.4

26

OL-23489-08

Image 26
Contents Managing Network Adapters Overview of the Cisco UCS C-Series Network AdaptersViewing Network Adapter Properties Cisco UCS P81E Virtual Interface CardProduct Name column Cimc Management EnabledPCI Slot column Serial Number columnNIV Mode field Configuration Pending fieldFIP Mode field FaultConfiguring Adapter Properties Click Save Changes Enable FIP Mode check boxEnable NIV Mode check box Number of VM FEX Interfaces Viewing vHBA Properties Managing vHBAsGuidelines for Managing vHBAs Name fieldDefault Vlan field FC SAN Boot check boxEnable Persistent LUN Binding Class of Service drop-down listPort Down Timeout field Enable FCP Error RecoveryLink Down Timeout field Ratov fieldThrottle Count field Interrupt Mode drop-down listFlogi Timeout field LUNs per Target fieldModifying vHBA Properties World Wide Node Name field Error Recovery area, update the following fields Fibre Channel Interrupt area, update the following fields Name Creating a vHBA Click Add vHBADeleting a vHBA VHBA Boot TableCreating a Boot Table Entry Fc1Deleting a Boot Table Entry VHBA Persistent BindingViewing Persistent Bindings Guidelines for Managing vNICs Managing vNICsRebuilding Persistent Bindings PCI Order field Viewing vNIC PropertiesTrust Host CoS check box Failback Timeout field Enable PXE Boot check boxEnable Uplink Failover check box Coalescing Type drop-down list Interrupt Count fieldCoalescing Time field Receive Queue Count fieldEnable Large Receive check box Enable TCP Rx OffloadEnable TCP Tx Offload Transmit Queue Ring Size fieldEnable TCP-IPv6 Extension RSS Modifying vNIC PropertiesAccess Ethernet Interrupt area, update the following fields Ethernet Transmit Queue area, update the following fields Enable TCP Receive Side Scaling Creating a vNIC Click Add vNICVirtual Machine Fabric Extender Managing VM FEXDeleting a vNIC Viewing Virtual FEX PropertiesProperties button Vlan Mode columnPXE Boot field Uplink Failover columnInterrupt Mode field Coalescing Type fieldEnable IPv4 RSS field Enable TCP SegmentationEnable Large Receive field Enable TCP-IPv4 RSS fieldClick Export Configuration Backing Up and Restoring the Adapter ConfigurationExporting the Adapter Configuration Tftp Server IP Address fieldClick Import Configuration Importing the Adapter ConfigurationRestoring Adapter Defaults Adapter Firmware Installing Adapter Firmware From a Local FileManaging Adapter Firmware Installing Adapter Firmware From a Tftp Server Install Firmware buttonResetting the Adapter Activating Adapter FirmwareOL-23489-08