Cisco Systems UCSCPCIECSC02 World Wide Port Name field, FC SAN Boot check box, Uplink Port field

Page 8

Managing Network Adapters

Viewing vHBA Properties

Name

Description

World Wide Port Name field

The WWPN associated with the vHBA.

 

To let the system generate the WWPN, select AUTO. To specify a

 

WWPN, click the second radio button and enter the WWPN in the

 

corresponding field.

FC SAN Boot check box

If checked, the vHBA can be used to perform a SAN boot.

Enable Persistent LUN Binding

If checked, any LUN ID associations are retained in memory until they

check box

are manually cleared.

Uplink Port field

The uplink port associated with the vHBA.

 

Note

This value cannot be changed for the system-defined vHBAs

 

 

fc0 and fc1.

MAC Address field

The MAC address associated with the vHBA.

 

To let the system generate the MAC address, select AUTO. To specify

 

an address, click the second radio button and enter the MAC address in

 

the corresponding field.

Default VLAN field

If there is no default VLAN for this vHBA, click NONE. Otherwise,

 

click the second radio button and enter a VLAN ID between 1 and 4094

 

in the field.

Class of Service drop-down list

The CoS for the vHBA.

 

Select an integer between 0 and 6, with 0 being lowest priority and 6

 

being the highest priority.

 

Note

This option cannot be used in NIV

 

 

mode.

Rate Limit field

The data rate limit for traffic on this vHBA, in Mbps.

 

If you want this vHBA to have an unlimited data rate, select OFF.

 

Otherwise, click the second radio button and enter an integer between

 

1 and 10,000.

 

Note

This option cannot be used in NIV

 

 

mode.

PCIe Device Order field

The order in which this vHBA will be used.

 

To let the system set the order, select ANY. To specify an order, select

 

the second radio button and enter an integer between 0 and 17.

EDTOV field

The error detect timeout value (EDTOV), which is the number of

 

milliseconds to wait before the system assumes that an error has

 

occurred.

Enter an integer between 1,000 and 100,000. The default is 2,000 milliseconds.

 

Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide, Release 1.4

8

OL-23489-08

Image 8 Contents
Managing Network Adapters Overview of the Cisco UCS C-Series Network AdaptersViewing Network Adapter Properties Cisco UCS P81E Virtual Interface CardCimc Management Enabled PCI Slot columnProduct Name column Serial Number column Configuration Pending field FIP Mode field NIV Mode field FaultConfiguring Adapter Properties Click Save Changes Enable FIP Mode check boxEnable NIV Mode check box Number of VM FEX Interfaces Managing vHBAs Guidelines for Managing vHBAsViewing vHBA Properties Name fieldFC SAN Boot check box Enable Persistent LUN BindingDefault Vlan field Class of Service drop-down listEnable FCP Error Recovery Link Down Timeout fieldPort Down Timeout field Ratov fieldInterrupt Mode drop-down list Flogi Timeout fieldThrottle Count field LUNs per Target fieldModifying vHBA Properties World Wide Node Name field Error Recovery area, update the following fields Fibre Channel Interrupt area, update the following fields Name Creating a vHBA Click Add vHBAVHBA Boot Table Creating a Boot Table EntryDeleting a vHBA Fc1Deleting a Boot Table Entry VHBA Persistent BindingViewing Persistent Bindings Guidelines for Managing vNICs Managing vNICsRebuilding Persistent Bindings PCI Order field Viewing vNIC PropertiesTrust Host CoS check box Failback Timeout field Enable PXE Boot check boxEnable Uplink Failover check box Interrupt Count field Coalescing Time fieldCoalescing Type drop-down list Receive Queue Count fieldEnable TCP Rx Offload Enable TCP Tx OffloadEnable Large Receive check box Transmit Queue Ring Size fieldEnable TCP-IPv6 Extension RSS Modifying vNIC PropertiesAccess Ethernet Interrupt area, update the following fields Ethernet Transmit Queue area, update the following fields Enable TCP Receive Side Scaling Creating a vNIC Click Add vNICManaging VM FEX Deleting a vNICVirtual Machine Fabric Extender Viewing Virtual FEX PropertiesVlan Mode column PXE Boot fieldProperties button Uplink Failover columnInterrupt Mode field Coalescing Type fieldEnable TCP Segmentation Enable Large Receive fieldEnable IPv4 RSS field Enable TCP-IPv4 RSS fieldBacking Up and Restoring the Adapter Configuration Exporting the Adapter ConfigurationClick Export Configuration Tftp Server IP Address fieldClick Import Configuration Importing the Adapter ConfigurationRestoring Adapter Defaults Adapter Firmware Installing Adapter Firmware From a Local FileManaging Adapter Firmware Installing Adapter Firmware From a Tftp Server Install Firmware buttonResetting the Adapter Activating Adapter FirmwareOL-23489-08
Related manuals
Manual 204 pages 40.67 Kb