To install the mounting bracket

4 - PC3500TX Terminal Installation & User’s Guide

To install the mounting bracket

Locate a flat wall surface. Make sure you can plug the terminal into a 110VAC wall outlet (220VAC in Europe and other areas), which should be no farther than 4 feet from the terminal.

Place the bottom of the mounting template on the wall 48 inches from the floor and tape the template into place.

Drill the 3 holes noted on the template using a 5/16” drill bit. If wires will be routed through the wall, drill up to a 3/4" hole as indicated on the template. Remove the template.

Insert a wall anchor in each of the 5/16" holes and tap with a hammer until flush with the wall.

Align the mounting bracket with the anchors, (pull wiring through the hole in the middle of the case if wires are being routed from the wall), insert the 3 screws and tighten with a phillips head screwdriver.

Image 8
Contents PC3500TX Terminal Installation & User’s GuideLimited One-Year Limited Warranty PayClock, Lathem and the Lathem logo are registered trademarks of Lathem Time Corporation. Other product names SETUP THE TERMINAL INSTALL/REPLACE THE OPTIONAL BACKUP BATTERYOPTIONAL SIGNAL DEVICE NETWORK WIRING TOPOLOGIESFeatures and Specifications WelcomeC H A P T E R PC3500TX NOTICE - For Firmware 177B and EarlierPower Surges and Spikes Note about Lithium BatteryMount the Terminal Pre-Terminal InstallationMounting the Terminal To install the mounting bracket Turn the key clockwise to lock the terminal in place Connect the Communication Cable Setup the Terminal Starting the Test and Setup ModeSubnet Mask Network Test Not UsedPlug the terminal 12VDC power supply into the power connector To power up the terminal8 - PC3500TX Terminal Installation & User’s Guide Setup Mode - 177B Firmware For PayClock Pro 3.355G and earlier To Setup the PC3500TX’s Ethernet CommunicationsHIT ENTER IF DEFAULT ROUTE REQUIRED TERMINAL IP ADDRESS ###. ###. ###. ###HOST IP ADDRESS ###. ###. ###. ### NETWORK MASK ###. ###. ###. ###ENETADD=XXXXXXXXXXXX SETUP COMPLETE TCP/IP Conn. Type Setup Mode - 177G Firmware For PayClock Pro 4.1 and laterEnet MAC Address XXXXXXXXXXXX Default Router? TCP/IP Conn. ModeEnter Socket Port # Enter Terminal IP ###. ###. ###. ###Enter Sub Net Mask ###. ###. ###. ### Enter Keepalive ModeTest Mode To start the Test Mode“TEST MODE” PROG# TEST MODE 128 YYBattery Test BATTERY TEST PASS ENTER TO RETESTNote If you do not have a battery installed, the test will fail SWITCH TEST SWITCH TO USE POSITIONUnlocking Your Terminal Through Terminal Manager Restart ModeTo restart the terminal PRESS ENTER TO CLEAR ALL TRANSACTION DATAUse the Terminal To punchTo transfer To start a New DayTo enter amounts To review your last punchWhen you see BADGE FOR SUPERVISOR OVERIDE, swipe your badge When you see ENTER ASSOCIATES BADGE, swipe the employee’s badgeSupervisor Functions To see employee InfoInstall/Replace the Optional Backup Battery A P P E N D I X AOptional Signal Device GENERAL SPECIFICATIONSTo connect your signaling devices A P P E N D I X BA P P E N D I X C Network Wiring TopologiesTypical Lan network configuration Typical Wan network configuration 24 - PC3500TX Terminal Installation & User’s GuideTroubleshooting the Terminal 26 - PC3500TX Terminal Installation & User’s Guide Problem The terminal is not communicating with the computerProblem A previously working terminal now is not operational Reason TEST/USE switch is not in the Use positionProblem The terminal does not accept badge data Reason Bar code badge is not manufactured to specificationsSolution Refer to vendor’s manufacturing specifications Solution Ensure the badge stripe faces away from the keypad28 - PC3500TX Terminal Installation & User’s Guide Solution Open the PC3500TX’s Terminal Properties in Terminal ManagerClick OK to save the changes Update the terminal with the changes Select the Advanced tabTerminal Data Sheet A P P E N D I X D