Mitsubishi Electronics HS-S8300E(BRS) operation manual Maintenance

Page 11

2 SETTING THE FREQUENCY DIVISION RATIO (CLOCK OUT)

Sets the frequency division ratio of the CLOCK OUT terminal.

First, set the recording mode for the “CLOCK OUT” pulse output in the “REAR TERMINAL” menu.

REC:

When recording in any mode.

T/L-REC:

When recording in time lapse mode (L12H, L24H, 48H, 72H, 96H, 120H, 168H, 240H, 360H, 480H, 720H, 960H or 0H).

Second, select the frequency division ratio setting by turning the SHUTTLE ring. When the JOG dial is turned, the display will be switched in the order of 1 } 2 } 3 } 4 } 5 } 10 } 15 } 20 } 25 } 30 } 50 } 60 } F (field) } 1 } ... The numbers from 1 to 60 indicate the number of frames in 3H recording mode or the number of fields in time lapse recording mode. (One frame consists of two fields.) One field is selected when it is set to “F” (field).

3SETTING THE OPERATION MODE OF THE MODE OUTPUT TERMINAL (MODE OUT)

Set the state in which the signal output at the MODE OUT terminal is switched to the active condition. When the JOG dial is turned, the display will be switched on in the order of REC(recording) } PLAY(playback) } POWER (power “ON”) } TAPE IN (tape is inserted) } TAPE REMAIN (3 minutes in 3H mode before the tape end) } CLOCK ADJ (output the signal for 1 second when the clock indicates “00(min.):00(sec.)”) } REC

4SETTING THE OPERATION MODE OF THE REC IN TERMINAL (REC IN)

SERIES:

Recording starts when the REC IN terminal is short-circuited to ground or a “L” level voltage (0 - +1.6V) is

 

applied.

REC-START/ STOP: Recording starts when the REC IN terminal is short-circuited to ground or a “L” level voltage (0 - +1.6V) is

 

applied. Should this connection be removed, recording will stop.

SYNC REC:

The video signal from 5 or 9 cameras can be recorded separately by connecting a switcher. (“SYNC REC”

 

function is available when recording in L12H or L24H mode.) Refer to “SYNCHRONOUS RECORDING” on

 

page 18.

MAINTENANCE

1DISPLAYING THE POWER LOSS LIST (POWER LOSS LIST)

Turn the JOG dial to select “POWER LOSS LIST”. Turn the SHUTTLE ring to the right to display the Power Loss List. Power failure start times are stored in memory, so it is possible to confirm when they have occurred. Up to 3 power failure start times will be displayed. If more than 3 failures have occurred, the first and last 2 power failure start times will be displayed.

2DISPLAYING THE ALARM LIST (ALARM LIST)

<MAINTENANCE>

POWER LOSS LIST ALARM LIST

ALL MENU INITIALIZE POWER LOSS LIST CLEAR ALARM LIST CLEAR

<REPEAT REC TIMES>

0

<ELAPSED TIME>

0H

Turn the JOG dial to select “ALARM LIST”. Turn the SHUTTLE ring to the right to display the Alarm List. Alarm record start times are stored in memory, so it is possible to confirm when they have occurred. Up to 3 alarm record start times will be displayed. If more than 3 alarm records have occurred, the first and the last 2 alarm record start times will be displayed.

3INITIALIZING ALL MENU SETTINGS (ALL MENU INITIALIZE)

Turn the SHUTTLE ring to the right and “ALL MENU INITIALIZE” will be displayed. When the SHUTTLE ring is turned to the left, each setting is initialised except the TIMER RECORDING setting. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.

4CLEARING THE POWER LOSS LIST (POWER LOSS LIST CLEAR)

Turn the SHUTTLE ring to the right and “POWER LOSS LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the left, the Power Loss List is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.

5CLEARING THE ALARM LIST (ALARM LIST CLEAR)

Turn the SHUTTLE ring to the right and “ALARM LIST CLEAR” will be displayed. When the SHUTTLE ring is turned to the left, the alarm list is cleared. When the SHUTTLE ring is turned to the right, the “MAINTENANCE” menu will be displayed.

11

Image 11
Contents VHS HS-S8300EBRSUnplugging the Mains Lead When not in USEInstallation Location Condensation is the Enemy of Video RecordersFeatures ContentsFluorescent display Features and FunctionsFront View Fluorescent Display RECRear View Features and FunctionsReset button Sensor Connecting with Other Equipment Present Time Display Setting the Menus Present time display will appear Time Date Search Timer ProgramDisplay Rear Terminal Setting the MenusRecording SET UP Maintenance First Time SET UP FRI Setting the Present TimeDisplay mode Setting the Present Time to the Exact Second Setting the Present TimePreventing Accidental Erasure Loading and Unloading the Cassette TapeLoading UnloadingRecording Check Function REC ModeLock Mode Manual RecordingRecommended Number of Tape USE Stop Rewind Repeat AlarmprotRepeat Recording Number of Tape USE Repeat REC TimesConnection Manual RecordingONE SHOT/INTERVAL Recording Synchronous RecordingAdditional Features Timer Recording Symptom Fault Action Order to Avoid Mistakes When Using the Timer1st VCR Alarm RecordingAlarm Recording Connection External Time Clock AdjustmentEmergency Recording Setting for Alarm RecordingIndex Search Alarm RecordingAlarm Record Time Display Locating the Start of Alarm RecordingsAudio Playback Playback ModePlayback Still Picture Special Effects PlaybackShuttle Ring Direct Shuttle RingWhen the picture is vibrating Adjustment During PlaybackTracking Adjustment Picture Quality AdjustmentConnecting the VCR to a personal computer Using with the Personal ComputerConfiguring the Time Lapse VCR Setting Stop BIT Length RS-232C SettingSetting Transmission Rate Setting Data BIT LengthPhysical protocol of RS-232C Using with the Personal ComputerConnecting to a Personal Computer Data Communications SettingsCommand carried out Command Commands sent to the VCR FormatPower on command Command receivedCommand carried out VCR02 Command ParameterCommand for fast forwarding VCR02 Command received VCR02Commands and Responses 171=TIME Date Adjust + STOP=0, REWIND=1, REPEAT=2 +0=SERIES, 1=REC-START/STOP =SYNC REC Error codesDisplay Self Diagnostic FunctionFluorescent Monitor Cause Remedy To Turn OFF the IndicationIs the Lock indicator illuminated? Before Calling for ServiceSymptom Remedy Control INPUT/OUTPUT Signals and Circuits Label B-7 Control INPUT/OUTPUT Signals and CircuitsCircuit Connectors Specifications872C193C3