Mitsubishi Electronics HS-S8300E(BRS) Control INPUT/OUTPUT Signals and Circuits, Label B-7

Page 40

CONTROL INPUT/OUTPUT SIGNALS AND CIRCUITS

2REMOTE jack

Circuit

Shielded

MJ cable R R

SW

SW

R

SW

SW

 

 

 

 

1

2 ····································31 32

 

 

 

1)Resistor R:

Metal film resistor 1/4W 33kohms ±1%,

 

 

 

 

 

 

 

temperature factor ±100ppm/°C.

 

 

 

 

2)Button switch:

Momentary, ON resistor 200ohms or under.

 

 

 

3)Connector MJ:

Miniature jack, 2.5mm in diameter, comply with JISC6560.

 

 

 

Operational conditions

 

 

 

 

 

 

 

 

1)Isolation resistor:

200Mohms or over (in connector MJ)

 

 

 

 

2)Floating capacity:

0.1µF or under (in connector MJ).

 

 

 

 

3)Environmental temperature:

5-40°C (common with VCR).

 

 

 

 

 

 

4)Relative temperature:

Max. 80% (common with VCR).

 

 

 

 

 

 

 

 

Remote control switch functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Position

Function

Position

Function

 

Position

Function

Position

Function

1

STOP

 

9

3H

 

17

POWER ON/OFF

25

DOWN POSITION/SHIFT

 

2

RECORDING

 

10

L24H

 

18

REVERSE FRAME SHIFT

26

UP POSITION/SHIFT

3

PAUSE

 

11

48H

 

19

TIME DATE SEARCH

27

CLEAR

 

4

PLAYBACK

 

12

72H

 

20

INDEX SEARCH

28

START/END

 

5

REVERSE PLAYBACK

 

13

120H

 

21

( )DISPLAY/SET

29

( )REC/PLAY MODE

 

6

FORWARD FRAME SHIFT

 

14

240H

 

22

(+)DISPLAY/SET

30

(+)REC/PLAY MODE

 

7

FAST FORWARD

 

15

0H

 

23

LEFT POSITION/SHIFT

31

SKIP SEARCH

 

8

REWIND

 

16

 

24

RIGHT POSITION/SHIFT

32

TIMER RECORDING

2Remote Control (optional)

The optional Remote Control (R-7100) provides remote operation of the VCR.

Before using the remote control, put the label on it as shown in Fig.

No function is available.

REC/PLAY MODE

 

Label (B-7)

3H

L24H

PLAY

STOP

REC

 

 

 

PAUSE

 

 

 

/STILL

 

 

REV

 

 

 

FR ADV

PLAY

 

 

 

 

 

 

 

 

 

/REW FF/

40

Image 40
Contents HS-S8300EBRS VHSWhen not in USE Installation LocationCondensation is the Enemy of Video Recorders Unplugging the Mains LeadContents FeaturesFront View Features and FunctionsFluorescent display REC Fluorescent DisplayReset button Features and FunctionsRear View Connecting with Other Equipment SensorPresent time display will appear Setting the MenusPresent Time Display Display Timer ProgramTime Date Search Recording SET UP Setting the MenusRear Terminal Maintenance First Time SET UP Display mode Setting the Present TimeFRI Setting the Present Time Setting the Present Time to the Exact SecondLoading and Unloading the Cassette Tape LoadingUnloading Preventing Accidental ErasureREC Mode Lock ModeManual Recording Recording Check FunctionStop Rewind Repeat Alarmprot Repeat RecordingNumber of Tape USE Repeat REC Times Recommended Number of Tape USEManual Recording ONE SHOT/INTERVAL RecordingSynchronous Recording ConnectionAdditional Features Timer Recording Order to Avoid Mistakes When Using the Timer Symptom Fault ActionAlarm Recording Alarm Recording ConnectionExternal Time Clock Adjustment 1st VCRSetting for Alarm Recording Emergency RecordingAlarm Recording Alarm Record Time DisplayLocating the Start of Alarm Recordings Index SearchPlayback Playback ModeAudio Playback Special Effects Playback Shuttle RingDirect Shuttle Ring Still PictureAdjustment During Playback Tracking AdjustmentPicture Quality Adjustment When the picture is vibratingConfiguring the Time Lapse VCR Using with the Personal ComputerConnecting the VCR to a personal computer RS-232C Setting Setting Transmission RateSetting Data BIT Length Setting Stop BIT LengthUsing with the Personal Computer Connecting to a Personal ComputerData Communications Settings Physical protocol of RS-232CCommand Commands sent to the VCR Format Power on commandCommand received Command carried outCommand Parameter Command for fast forwarding VCR02Command received VCR02 Command carried out VCR02Commands and Responses 171=TIME Date Adjust + STOP=0, REWIND=1, REPEAT=2 Error codes +0=SERIES, 1=REC-START/STOP =SYNC RECSelf Diagnostic Function Fluorescent MonitorCause Remedy To Turn OFF the Indication DisplaySymptom Remedy Before Calling for ServiceIs the Lock indicator illuminated? Control INPUT/OUTPUT Signals and Circuits Circuit Control INPUT/OUTPUT Signals and CircuitsLabel B-7 Specifications Connectors872C193C3