Mitsubishi Electronics HS-S8300E(BRS) operation manual Specifications, Connectors

Page 41

SPECIFICATIONS

Tape Format:

VHS 1/2" width high-density video cassette tape.

 

 

 

 

Power Source:

AC100-230V, 50/60Hz.

 

 

 

 

 

Power Consumption:

Approx.20watts.

 

 

 

 

 

 

Television System:

625 lines, 50 field PAL-type colour system.

 

 

 

 

Heads-Video:

4 rotary single crystal heads.

 

 

 

 

 

Luminance Signal:

Frequency modulation recording.

 

 

 

 

 

Colour Signal:

Low frequency conversion, sub-carrier phase shift recording.

 

 

 

Audio Track:

1 track.

 

 

 

 

 

 

 

Tape Speed and Recording

 

 

 

 

 

 

 

 

Time (with E-180 cassette):

Mode

Time

Speed

Recording interval

Video signal

Audio signal

Tape drive

 

3H

3hrs

23.39mm/sec

20msec./Field

Continuous

Recordable

Continuous

 

L12H

15hrs

4.68mm/sec

100msec./Field

Time lapse

Recordable

Continuous (Slow)

 

L24H

27hrs

2.60mm/sec

180msec./Field

Time lapse

Recordable

Continuous (Slow)

 

48H

51hrs

340msec./Field

Time lapse

Not recorded

Time lapse

 

72H

75hrs

500msec./Field

Time lapse

Not recorded

Time lapse

 

96H

99hrs

660msec./Field

Time lapse

Not recorded

Time lapse

 

120H

123hrs

820msec./Field

Time lapse

Not recorded

Time lapse

 

168H

171hrs

1140msec./Field

Time lapse

Not recorded

Time lapse

 

240H

243hrs

1620msec./Field

Time lapse

Not recorded

Time lapse

 

360H

363hrs

2420msec./Field

Time lapse

Not recorded

Time lapse

 

480H

483hrs

3220msec./Field

Time lapse

Not recorded

Time lapse

 

720H

723hrs

4820msec./Field

Time lapse

Not recorded

Time lapse

 

960H

963hrs

6420msec./Field

Time lapse

Not recorded

Time lapse

 

0H

 

Time lapse

Not recorded

Time lapse

Fast Forward/Rewind Time:

Approx. 140sec. with E-180 cassette.

 

 

 

 

 

Audio/Control:

1 stationary head.

 

 

 

 

 

 

Erase:

1 full-track head.

 

 

 

 

 

 

Motors:

3 motors-drum/capstan direct drive system.

 

 

 

 

Video Input:

1.0Vp-p, 75ohms BNC plug. Y: 1.0 Vp-p, 75 ohms,

C: 0.286 Vp-p, 75 ohms, S-connector.

 

Audio Input:

-8dBs, 50kohms, RCA plug.

 

 

 

 

 

Microphone Input:

-67dBs, 600ohms, mini mic jack.

 

 

 

 

 

Video Output:

1.0Vp-p, 75ohms BNC plug. Y: 1.0 Vp-p, 75 ohms,

C: 0.286 Vp-p, 75 ohms, S-connector.

 

Audio Output:

-6dBs, 1kohms, RCA plug.

 

 

 

 

 

Horizontal Resolution:

More than 400 lines (S-VHS mode).

 

 

 

 

 

 

More than 240 lines (VHS mode).

 

 

 

 

 

Audio Frequency Response:

70Hz- 7kHz (3H mode).

 

 

 

 

 

Signal-to-Noise Ratio:

Video: better than 42dB.

 

 

 

 

 

 

Audio: better than 43dB.

 

 

 

 

 

Operating Temperature:

41°F-104°F (5°C to 40°C).

 

 

 

 

 

Relative Humidity:

Max.80(%)

 

 

 

 

 

 

 

Dimensions:

16.7(W)x12.4(D)x3.7(H)(in.).

 

 

 

 

 

(Jog dial included)

425(W)x315(D)x93(H)(mm).

 

 

 

 

 

Weight:

10 lbs (4.5kg.)

 

 

 

 

 

 

Alarm Recording Time:

Timed: 15 sec/30 sec/45 sec/1 min./2 min./5 min./10 min.

 

 

 

Display Format:

Manual 1: Until the alarm reset switch is switched on. Manual 2: Until the alarm set switch is switched off.

DISPLAY MODE 1: (Day)-(Month)-(Year) (Hour) : (Minute) : (Second) (Daylight saving time symbol or power failure symbol) (Alarm recording no.)

 

DISPLAY MODE 2: (Month)-(Day)-(Year) (Day of week) (Alarm recording no.),

 

 

 

 

 

(Hour) : (Minute) : (Second) (Daylight saving time symbol or power failure symbol) (Recording mode)

 

Display Position:

In any position.

 

 

 

 

 

 

Memory Program:

8 programs- daily start and stop time for one week.

 

 

 

 

Memory Backup:

Lasts 31days.

 

 

 

 

 

 

Elapsed Time Indicator:

The maximum of 89,999 hours.

 

 

 

 

 

CONNECTORS

 

 

 

 

 

 

 

 

SET Input:

Screw terminal for starting alarm recording.

 

 

 

 

RST Input:

Screw terminal for finishing alarm recording or for adjusting on-screen clock.

 

 

REC Input:

Screw terminal for starting/finishing recording, for series recording or for synchronous recording.

GND:

Screw terminal for ground.

 

 

 

 

 

ALM Output:

Screw terminal for output while alarm recording is under way.

 

 

 

CLK Output:

Screw terminal to command camera switching.

 

 

 

 

MODE Output:

Screw terminal for indication of VCR selected mode.

 

 

 

CALL Output:

Screw terminal for external warning device or for series recording.

 

 

REMOTE Jack:

Jack for connecting the remote control unit.

 

 

 

 

RS-232C interface:

D-SUB 9 pin connector.

 

 

 

 

 

Rating:

 

 

 

 

 

 

 

 

ALM/CALL/MODE

Active: “Low” level, max. Current 50mA (+5VDC)/10mA (+24VDC).

 

 

 

Non active: Open, max. Voltage +24V DC.

 

 

 

 

SET/RST/REC

Active: When terminals are short-circuited or “Low” level voltage applied.

 

 

 

Non active: Open, max. Voltage +17V DC.

 

 

 

 

CLK

Recording: A pulse of the frequency division ratio selected by REAR TERMINAL menu.

 

Weight and dimensions shown are approximate.

Design and specifications are subject to change without notice.

41

Image 41
Contents VHS HS-S8300EBRSInstallation Location When not in USECondensation is the Enemy of Video Recorders Unplugging the Mains LeadFeatures ContentsFluorescent display Features and FunctionsFront View Fluorescent Display RECRear View Features and FunctionsReset button Sensor Connecting with Other EquipmentPresent Time Display Setting the MenusPresent time display will appear Time Date Search Timer ProgramDisplay Rear Terminal Setting the MenusRecording SET UP Maintenance First Time SET UP FRI Setting the Present TimeDisplay mode Setting the Present Time to the Exact Second Setting the Present TimeLoading Loading and Unloading the Cassette TapeUnloading Preventing Accidental ErasureLock Mode REC ModeManual Recording Recording Check FunctionRepeat Recording Stop Rewind Repeat AlarmprotNumber of Tape USE Repeat REC Times Recommended Number of Tape USEONE SHOT/INTERVAL Recording Manual RecordingSynchronous Recording ConnectionAdditional Features Timer Recording Symptom Fault Action Order to Avoid Mistakes When Using the TimerAlarm Recording Connection Alarm RecordingExternal Time Clock Adjustment 1st VCREmergency Recording Setting for Alarm RecordingAlarm Record Time Display Alarm RecordingLocating the Start of Alarm Recordings Index SearchAudio Playback Playback ModePlayback Shuttle Ring Special Effects PlaybackDirect Shuttle Ring Still PictureTracking Adjustment Adjustment During PlaybackPicture Quality Adjustment When the picture is vibratingConnecting the VCR to a personal computer Using with the Personal ComputerConfiguring the Time Lapse VCR Setting Transmission Rate RS-232C SettingSetting Data BIT Length Setting Stop BIT LengthConnecting to a Personal Computer Using with the Personal ComputerData Communications Settings Physical protocol of RS-232CPower on command Command Commands sent to the VCR FormatCommand received Command carried outCommand for fast forwarding VCR02 Command ParameterCommand received VCR02 Command carried out VCR02Commands and Responses 171=TIME Date Adjust + STOP=0, REWIND=1, REPEAT=2 +0=SERIES, 1=REC-START/STOP =SYNC REC Error codesFluorescent Monitor Self Diagnostic FunctionCause Remedy To Turn OFF the Indication DisplayIs the Lock indicator illuminated? Before Calling for ServiceSymptom Remedy Control INPUT/OUTPUT Signals and Circuits Label B-7 Control INPUT/OUTPUT Signals and CircuitsCircuit Connectors Specifications872C193C3