Mitsubishi Electronics HS-S8300E(BRS) Manual Recording, ONE SHOT/INTERVAL Recording, Connection

Page 18

MANUAL RECORDING

ONE SHOT/INTERVAL RECORDING

One-shot recording or Interval recording is possible when the recording mode is set to 0H.

1Press the REC/PLAY MODE button to set the recording mode to 0H.

2Set the number of fields in “ONE SHOT•FIELD” on the “RECORDING SET UP” menu.

3 For One-shot recording, select “SHOT” in “ONE SHOT•INTERVAL”.

For Interval recording, choose the interval time from 10S(second) to 3M(minute) in “ONE SHOT•INTERVAL”.

4 Press the REC button.

One-shot recording will be on STANDBY mode. Interval recording begins recording with the preset interval time. 5 To start One-shot recording, press the REC button or switch the REC IN terminal on the rear panel to ground.

SYNCHRONOUS RECORDING

A number of camera images can be mixed together through a camera switcher and then recorded separately onto several VCRs. A camera is assigned to each VCR with the VCR recording only the camera image it has been assigned. This allows recording without gaps.

If you have three VCRs, the video signal from three cameras can be recorded separately by connecting the switcher as shown below.

V-SYNC

SWITCHER/ switching cameras

/ recording start signal

CAMERA1 CAMERA2 CAMERA3 CAMERA4 CAMERA5 CAMERA1 CAMERA2 CAMERA3 CAMERA4 CAMERA5

VCR 1

/ recording

 

/ clock out

VCR 2

/ recording

 

/ clock out

VCR 3

/ recording

 

/ clock out

VCR 4

/ recording

 

/ clock out

VCR 5

/ recording

 

/ clock out

REC

REC

REC REC

REC REC

REC REC

REC REC

Connection:

CAMERA 1

CAMERA 2

CAMERA 3

CAMERA 4

CAMERA 5

 

VIDEO IN

VCR1

 

 

 

SWITCHER

VCR2

 

 

 

 

VCR3

CAMERAS

 

VCR4

 

 

VCR5

CLK OUT

REC IN CLK OUT

REC IN CLK OUT

REC IN CLK OUT

REC IN

Set the “REC IN” of “REAR TERMINAL” menu to “SERIES” or “REC-START/STOP” on VCR1. Set the “CLOCK OUT” of “REAR TERMINAL” menu to “T/L-REC” and “F” on VCR1.

Set the “REC IN” of “REAR TERMINAL” menu to “SYNC REC” on all VCRs except VCR1.

If recording start signal is available on switcher, set the “REC IN” of the “REAR TERMINAL” menu to “SYNC REC” on VCR1. Then, VCR1 will always record the picture from CAMERA1.

You must set the recording mode to L12H or L24H mode.

The suitable numbers of VCRs and cameras are shown in the table.

Recording mode

VCR

Camera

 

L12H

5

Multiple of 5

 

L24H

9

Multiple of 9

18

 

 

 

Image 18
Contents HS-S8300EBRS VHSCondensation is the Enemy of Video Recorders When not in USEInstallation Location Unplugging the Mains LeadContents FeaturesFeatures and Functions Front ViewFluorescent display REC Fluorescent DisplayFeatures and Functions Reset buttonRear View Connecting with Other Equipment SensorSetting the Menus Present time display will appearPresent Time Display Timer Program DisplayTime Date Search Setting the Menus Recording SET UPRear Terminal Maintenance First Time SET UP Setting the Present Time Display modeFRI Setting the Present Time Setting the Present Time to the Exact SecondUnloading Loading and Unloading the Cassette TapeLoading Preventing Accidental ErasureManual Recording REC ModeLock Mode Recording Check FunctionNumber of Tape USE Repeat REC Times Stop Rewind Repeat AlarmprotRepeat Recording Recommended Number of Tape USESynchronous Recording Manual RecordingONE SHOT/INTERVAL Recording ConnectionAdditional Features Timer Recording Order to Avoid Mistakes When Using the Timer Symptom Fault ActionExternal Time Clock Adjustment Alarm RecordingAlarm Recording Connection 1st VCRSetting for Alarm Recording Emergency RecordingLocating the Start of Alarm Recordings Alarm RecordingAlarm Record Time Display Index SearchPlayback Mode PlaybackAudio Playback Direct Shuttle Ring Special Effects PlaybackShuttle Ring Still PicturePicture Quality Adjustment Adjustment During PlaybackTracking Adjustment When the picture is vibratingUsing with the Personal Computer Configuring the Time Lapse VCRConnecting the VCR to a personal computer Setting Data BIT Length RS-232C SettingSetting Transmission Rate Setting Stop BIT LengthData Communications Settings Using with the Personal ComputerConnecting to a Personal Computer Physical protocol of RS-232CCommand received Command Commands sent to the VCR FormatPower on command Command carried outCommand received VCR02 Command ParameterCommand for fast forwarding VCR02 Command carried out VCR02Commands and Responses 171=TIME Date Adjust + STOP=0, REWIND=1, REPEAT=2 Error codes +0=SERIES, 1=REC-START/STOP =SYNC RECCause Remedy To Turn OFF the Indication Self Diagnostic FunctionFluorescent Monitor DisplayBefore Calling for Service Symptom RemedyIs the Lock indicator illuminated? Control INPUT/OUTPUT Signals and Circuits Control INPUT/OUTPUT Signals and Circuits CircuitLabel B-7 Specifications Connectors872C193C3