Major operations and their functions (continued)
Rear view (continued)
3 | 4 | 5 6 7 | 8 | 9 | 10 |
IN | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
OUT | |||||||||
|
|
|
|
|
|
|
| ||
|
|
|
| CAMERA |
|
|
|
| |
IN | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | |
OUT | |||||||||
|
|
|
|
|
|
|
| ||
|
| CLAMPER |
|
|
|
|
|
|
VIDEO VIDEO
Y/C
OUTPUT A OUTPUT B
CLAMPER
OUT IN
VIDEO CASCADE
SERIAL BUS SERIAL BUS
AUDIO IN
1 | 2 |
3 | 4 |
OUT | IN |
AUDIO | CASCADE |
| AUDIO OUT |
OPTION SLOT
AC IN~
MAIN
OFF ON
1 2
GND
11 12
ALARM OUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
13
RESET |
ALARM IN |
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 |
14 |
100 |
|
|
|
|
| 10 100 |
| 10 |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
| STORAGE |
|
| COM |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CLOCKADJ | ADJCLOCKOUT | REC | STOPREC | EMERGENCY | RESERVED | OUTMODE1 + | OUTMODE1— | OUTMODE2 + | OUTMODE2— | OUTMODE3 + | OUTMODE3— | OUTMODE4 + | OUTMODE4— | OUTCALL+ | OUTCALL— | 350mAMAX 12VDCOUT |
|
|
|
|
| TERMRS485+ | TERMRS485— | RS422+ RS422— | RS232 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RS485 | RS485 |
|
| P T Z |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUT | IN |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15 16 17
13.ALARM IN terminals
Input terminals for alarm signal.
ALARM OUT terminals
Output terminals for alarm signal.
14.RESET button
Used to reset the unit and turn off the power. At this time, picture data, menu settings, and the present time are kept.
15.I/O terminals
CLOCK ADJ terminal
Input terminal to set the present time. Time display is adjusted to the nearest hour (00 minutes 00 sec- onds) when this terminal receives the CLOCK ADJ signal.
•The
CLOCK ADJ OUT terminal
Output terminal to send the signal to the other recorders connected for adjusting the clock to the nearest hour (00 minutes 00 seconds).
REC terminal
Input terminal to start recording. This terminal is not available during timer recording.
REC STOP terminal
Input terminal to stop recording. This terminal is not available during timer recording.
EMERGENCY terminal
Input terminal to start EMERGENCY recording im- mediately.
MODE OUT 1 to MODE OUT 4 terminals
Output terminal to indicate the current mode of this unit. Select the mode of the unit to be output in the <Mode Out Settings> (Setup MenuSystemRear Terminal SettingMode Out Settings).
CALL OUT terminals/CALL OUT GND terminal
This is a ISOLATION output terminal. Information to be transmitted externally consists of CALL OUT settings made in the <Call Out Settings> (Setup MenuSystemRear Terminal SettingCall Out Settings) as well as fixed output settings.
DC 12 V OUT terminal
Output the voltage only when both the MAIN switch and POWER button are turned ON. The maximum electric current is 350 mA.
16.RS485 IN/OUT connectors
Connectors for control of cascade recorders. Used to connect with the other recorders.
17.RS422/RS232C connectors
Connectors for connecting PTZ cameras to oper- ate pan, tilt, and zoom functions of the camera.
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Beginning