Recording Data Readout Setting
•You cannot set this item during recording or playback.
System Menu
5 Memory
4 Recording Data Readout Setting
(Playback Device Repeat Setting)
This item is used to repeat playback the recorded contents of the device.
step1. Select the desired repeat playback setting.
Repeat On: Automatically resumes playback from the beginning of the recording data when the recording data is played back to the end.
Repeat Off: Stops playback when the recording data is played back to the end.
(Image Originality Check Play)
This item is used to check whether the recording data is altered. “The alteration part is found in the data.” is dis- played when the alteration is detected.
step2. Select the desired setting.
Active: Image originality check is performed during playback, and a warning is displayed at the point containing alteration.
Inactive: Image originality check is not performed.
step3. Playback the data of the device to be checked.
•Image originality check play is performed only for the picture of the camera which is being played back and displayed on the monitor connected to OUTPUT A connector. Output B does not support originality check.
When the picture is played back on the monitor for both of the OUTPUT A and B, the image originality check play is executed not for all the playback picture on OUTPUT A.
•This function may cause problems during recording and playback. Normally, set this function to “Inactive.”
•Warning is also displayed for parts where recorded data is damaged for some reason.
•When performing complex playback operations with the SHUTTLE ring during alteration check, “The alteration part is found in the data.” warning may appear. Perform alteration check using playback or playback with changed playback intervals.
(Auto-Expire on Specified Date)
This item is used to disenable the data which is recorded before the specified time period to be played back in order to prevent keeping the data beyond the specified period.
step4. Select the desired time period.
•The data recorded before the set time period from the present time becomes disable to be played back. Only the data of set time period by calculating back from the present time can be played back.
Example
When setting to "2 Day":
Disable to be played back |
| 2 days |
|
|
|
| |||
|
|
|
|
|
Present time
•The available time period of the data to be played back is slightly longer than the set value because the picture is administrated in 2 MB unit.