LAN B (Communication) Setting
This item is used to make the communication settings between this unit and the PC connected via LAN B.
System Menu
1 COM/LAN
step 7
3 LAN B (Communication) Setting
step 1
1 LAN B Address Setting
step 2
2 Service Port Setting
step 3
3
step 4
D
step 5
4 IP Alarm Notification Information
step 6
D Alarm Notification Detailed Infomation
•Using the web function of this unit is required to input
(E-mail Notification Detailed Information)
step4. Check the contents to be transmitted to the PC.
Remain: Transmits signal when the remaining capacity reaches the value set for Call out setting. Temp/Fan: Transmits signal when the high temperature is detected or the fan is stopped.
Reboot: Transmits signal when the unit is rebooted.
Record: Transmits signal when the recording is started.
Alarm: Transmits signal when the alarm recording is started.
Sensor: Transmits signal when the signal is input to the terminal on the rear panel.
•Using the web function of this unit is required to change the contents to be transmitted.
(IP Alarm Notification Information)
step5. Check the settings of “IP Address” and “Target Port.”
•This item is used to transmit warning signals or signals of status change such as a closure of a rear terminal to the PC connected.
•When selecting “Test,” the sending test for the set IP address and port is executed.
(LAN B Address Setting)
step1. Set the IP address, sub net mask, and Gateway.
•MAC address is shown on the bottom of the screen of <LAN B (Communication) Setting>.
•Do not assign the same IP address or network address for LAN A and LAN B.
•Do not assign “000.000.000.000” to IP address and broadcast address. If this address is assigned, communications or any other functions of this unit may not be performed correctly.
•The setting cannot be changed during recording. Stop recording before changing the setting.
(Service Port Setting)
step2. Set the port setting of “Web,” “User Access,” and “Administrator.”
•This item is used to set the port number which is necessary to connect a PC.
•Normally, leave the setting as is.
•Do not change the setting without sufficient knowledge about the network setting.
•When making the settings other than the port settings of “Web,” “User Access,” and “Administrator,” using the specified application is required. Consult your dealer about the specified application.
(E-mail Notification Information)
step3. Check the settings of
•When selecting “Mail,” the
•Using the specified application is required to change the IP address and target port. Consult your dealer about the specified application.
•Transmission of signal to broadcast address is not supported.
(Alarm Notification Detailed Information)
step6. Check the contents to be transmitted to the PC.
Remain: Transmits signal when the remaining capacity reaches the value set for Call out setting. Temp/Fan: Transmits signal when the high temperature is detected or the fan is stopped.
Reboot: Transmits signal when the unit is rebooted.
Record: Transmits signal when the recording is started.
Alarm: Transmits signal when the alarm recording is started.
Sensor: Transmits signal when the signal is input to the terminal on the rear panel.
•Using the specified application is required to change the contents to be transmitted. Consult your dealer about the specified application.
step7. Select “Return” in the screen of <LAN B (Communication) Setting>.
•When the setting of “IP Address,” “Sub Net Mask,” “Gateway,” or “Service Port Setting” is changed, the power turns off automatically and then the unit restarts.