OPERATION (continued)
W.PAINT | GAIN SHUTTER IRIS MANU OPERATE |
ENTER
MENU FUNC1 FUNC2 /SET
B C D E
oGENLOCKING MODE ADJUSTMENTS
● Controls SC phase and horizontal phase during genlocking
1.Select A3: SC FINE COARSEB using MENU button B (SC phase adjustment).
3 : SC FINE COARSE
0 0°
SC FINE SC COARSE
2.Set the SC COARSE using FUNC2 button D (0°, 90°, 180° and 270°).
3.
Select ASC COARSEB
To |
|
direction. | FUNC1 FUNC2 |
|
To
●If the button is held depressed, the level will vary in 10 steps.
4.Select A4: H.PHASEB using MENU button B (horizontal phase adjustment).
4 : H. PHASE
0
Horizontal phase
5.Adjust the horizontal phase using FUNC1 button C
●If the button is held depressed, the level will vary in 10 steps.
To adjust phase in the |
|
+ direction. | FUNC1 |
|
To adjust phase in the
– direction.
oGAMMA CORRECTION (ON/OFF)
●Set to ON to correct gamma or to OFF when gamma correction is not required.
1.Select A5: GAMMAB using MENU button B.
2.Set to ON or OFF using FUNC2 button D.
Set ON or OFF.
FUNC2
5 : GAMMA
ON
Mode indication
oAUTO IRIS DETECTION MODE
● Three modes are available:
NORMAL | : Detection is based on a |
| combination of peak value and |
| average value. |
PEAK | : The peak value is detected, and |
| the optimum iris level is |
| adjusted. |
AVG | : The average value is detected, |
| then the optimum iris level is |
| adjusted. |
1.Select A6: IRIS DETECTB using MENU button
B.
6 : IRIS DETECT NORMAL
2.Select the detection mode using FUNC2 button
D.
●Each time is pressed, the mode changes from NORMAL N PEAK N AVG N NORMAL N...; pressing changes the modes in reverse order.
Select a detection
mode.FUNC2