3RECORD SET
13 Press the [EXIT] button.
The setting procedure is ended and the display returns to the normal screen.
EXIT
zThe recording rate is automatically calculated based on recording settings and the number of connected cameras, and this is indicated by “REC RATE”. All cameras will record at this rate. If a valid figure cannot be calculated, “ERROR!” will be displayed.
zWhen easy setup settings and individual settings are both set, the most recent settings override previous settings.
zEasy setup settings cannot be used with program recording or
Setting based on recording rate
4 Turn the jog dial to select “REC RATE BASE”, and then turn the shuttle dial clockwise.
The <REC RATE BASE> screen is displayed with the cursor positioned on “REC RATE”.
The number of detected cameras is indicated by
“NUMBER OF CAMERAS”.
zConfirm that the number of cameras connected to the digital video recorder is the same as the number of displayed recording cameras. If this is not the case, check the wiring between cameras and the digital video recorder and then carry out “CAMERA DETECT”. (JP.46)
5 Turn the shuttle dial clockwise.
“60.00” flashes.
6 Turn the jog dial to select “REC RATE”, and then turn the shuttle dial clockwise.
Set the recording rate for each individual camera.
The cursor moves to “TIMER RECORDING (DAY)”.
SETTINGS
7 Turn the shuttle dial clockwise.
“OFF” flashes.
8 To activate timer operation, turn the jog dial to select “ON”, and then turn the shuttle dial clockwise.
The cursor moves to “START”.
If timer recording has been set to “ON”, the timer’s “START” and “STOP” should now be set.