3RECORD SET
6 Turn the jog dial to set “DURATION” (10 SEC for example), and then turn the shuttle dial clockwise.
(Default setting: 1 MIN)
The cursor moves to “ALARM TRIGGER”.
When pre-alarm recording settings have been completed
Press the [EXIT] button.
EXIT
The setting procedure is ended and the display returns to the normal screen.
“PRE” appears in the operation display area. When an alarm occurs, “ALARM” is displayed.
Number of alarm
PRE display
02
z
As playback begins at the point of alarm occurrence, use the shuttle dial to move back into the area of pre- alarm recording.
zWhen normal recording and
Setting the alarm trigger
Use this setting to indicate how alarms are to be detected.
1 Turn the jog dial to select “ALARM TRIGGER”, and then turn the shuttle dial clockwise.
“ALARM” flashes in the “ALARM TRIGGER” field.
2 Turn the jog dial to select an alarm detection method, and then turn the shuttle dial clockwise.
[Settings] ( indicates the default setting)
Setting | Description | |
| Alarm recording is performed when an | |
| external alarm is generated (i.e., | |
ALARM | when a switch is attached to the alarm | |
| input terminal on the rear panel, and | |
| the switch is activated). | |
| Alarm recording is performed when a | |
SENSOR | motion sensor detects movement. | |
See the section on setting motion | ||
| ||
| sensors for more details. | |
ALARM AND | Alarm recording is performed when | |
both the external alarm and a motion | ||
SENSOR | ||
sensor are activated simultaneously. | ||
| ||
| Alarm recording is performed when | |
ALARM OR SENSOR | either the external alarm or a motion | |
| sensor is activated. |
[Setting conditions]
zWhen sensor selection has been made (i.e., “SENSOR”, “ALARM AND SENSOR”, or “ALARM OR SENSOR”) it will be necessary to set the motion sensors.
English | 71 |