3M 965DSP-B instruction manual Load Coils

Page 15

Load Coils

This function takes about one minute to count up to four load coils on the pair. You will see the word ‘Counting’ in the display while the test is in progress. You will see the word ’Done’ when then test is complete.

Press the [Enter] key at any time if you wish to stop the count earlier. The screen then shows the number of load coils counted and the word ‘Stopped’ on the screen.

If you are only looking to see if a line has load coils or not, you may elect to stop the test after one load coil has been detected.

After the test is done or was stopped, press the [Enter] key to repeat the load coil count. Press the [Back] key to return to the Toolbox menu.

Note that you must have 2000 feet (600 meters) before and after each load coil for the Load Coil function to count properly.

15

Image 15
Contents Dynatel TM 965DSP-B Subscriber Loop Analyzer Page Table of Contents Out of Box Screen Test LeadsKeypad Editing Control KeysFunction Keys Welcome Screen SetupContrast UnitsVoltage Current Resistance Toolbox Self-Calibration Load Coils Ohms/Distance Caller ID Opens Edit Custom Calibrate to Cable Tone Page Separate Pair This is the preferred hookup RFL Resistance Fault LocatePage RFL Single Pair Page RFL Multi-section Setup RFL SetupPage Isdn Isdn Bit Error Test Page Noise LossWideband Loss Longitudinal BalanceInactive Pair AutoActive Pair Auto SetupDial Loss Dial Noise/Longitudinal BalanceOpens Cable Type Talk Set Talk Set Setup AC/DC Adaptor Care and MaintenanceCharging Level of ChargeBattery Holder Replacement ItemsTest Leads Repair Symptom Cause Solution Unit does not turn on965DSP-B Specifications New Product Limited Warranty