3M instruction manual 965DSP-B Specifications

Page 42

965DSP-B Specifications:

Size:

4x10x2.5"

(10x25x6 cm)

Weight:

3.3 lbs

(1.5 kg)

Operating Temp:

0 to 140°F

(-18 to 60°C)

Storage Temp:

-40 to 165°F

(-40 to 70°C)

Function

Range

 

Accuracy

Voltage:

0 to 30 Vdc, Vac

0.5 V

 

30 to 300 Vdc

 

0.7 V

 

30 to 250 Vac

 

0.7 V

Current:

-60 to 60 mA

 

1% +/- 0.3 mA

 

-110 to -60 mA

 

2%

 

60 to 110 mA

 

2%

Resistance:

0 to 100kΩ

 

1% +/- 5 Ω

 

(1% +/- 50 Ω if C.O. voltage present)

 

100kΩ to 10MΩ

 

3%

 

100MΩ to 1000MΩ

10%

Load Coils:

Opens:

Tone:

RFL fault size: RFL loop resist.: RFL fault locate:

0 to 4

3 to 10000 ft

(1m to 3 km)

10000 to 50000 ft (3 to 15km)

50000 to 100000 ft

(15 to 30 km)

200 to 20kHz, -20 to +1 dB 40kHz, 6dBm

0to 20 MΩ

0to 7000 Ω

0to 99 Ω

100 to 999 Ω

1000 to 7000 Ω

1% +/- 3 ft

(1% +/- 1 m)

5%

10%

1Hz

0.2 dB 10Hz, 0.5dB

0.1% of RTS +/- 0.01 Ω 0.2% of RTS 1% of RTS

(RTS: Resistance to Strap. Distance to fault depends on the wire gauge and temperature selected.)

Loss:

-40 to 10 dBm

0.5 dB

 

200 to 3000 Hz

2 Hz

 

3 kHz to 20 kHz

10 Hz

Wideband Loss:

-46 to 10 dBm

1 dB

 

20k to 200kHz

100 Hz

Noise Metallic:

0 to 50 dBrnc

2 dB

Noise to Ground:

40 to 100 dBrnc

2 dB

Auto:

(Same as individual functions)

42

Image 42
Contents Dynatel TM 965DSP-B Subscriber Loop Analyzer Page Table of Contents Out of Box Screen Test LeadsKeypad Control Keys EditingFunction Keys Setup Welcome ScreenUnits ContrastVoltage Current Resistance Toolbox Self-Calibration Load Coils Ohms/Distance Caller ID Opens Edit Custom Calibrate to Cable Tone Page RFL Resistance Fault Locate Separate Pair This is the preferred hookupPage RFL Single Pair Page RFL Setup RFL Multi-section SetupPage Isdn Isdn Bit Error Test Page Loss NoiseLongitudinal Balance Wideband LossAuto Inactive PairAuto Setup Active PairDial Loss Dial Noise/Longitudinal BalanceOpens Cable Type Talk Set Talk Set Setup Level of Charge Care and MaintenanceCharging AC/DC AdaptorBattery Holder Replacement ItemsTest Leads Symptom Cause Solution Unit does not turn on Repair965DSP-B Specifications New Product Limited Warranty